English
Language : 

XC5VLX30-1FF676I Datasheet, PDF (6/91 Pages) Xilinx, Inc – Virtex-5 FPGA DC Characteristics
Virtex-5 FPGA Data Sheet: DC and Switching Characteristics
Power-On Power Supply Requirements
Xilinx® FPGAs require a certain amount of supply current
during power-on to insure proper device initialization. The
actual current consumed depends on the power-on ramp
rate of the power supply.
The power supplies can be turned on in any sequence,
though the specifications shown in Table 5 are for the
recommended power-on sequence of VCCINT, VCCAUX, and
VCCO. The I/O will remain 3-stated through power-on if the
recommended power-on sequence is followed. Xilinx does
not specify the current or I/O behavior for other power-on
sequences.
Table 5 shows the minimum current required by Virtex-5
devices for proper power-on and configuration.
If the current minimums shown in Table 5 are met, the
device powers on properly after all three supplies have
passed through their power-on reset threshold voltages.
The FPGA must be configured after VCCINT is applied.
Once initialized and configured, use the XPOWER tools to
estimate current drain on these supplies.
Table 5: Power-On Current for Virtex-5 Devices
Device
ICCINTMIN ICCAUXMIN
Typ(1)
Typ(1)
ICCOMIN
Typ(1)
Units
XC5VLX20T
172
54
50
mA
XC5VLX30
235
76
50
mA
XC5VLX30T
246
86
50
mA
XC5VLX50
320
114
50
mA
XC5VLX50T
336
124
50
mA
XC5VLX85
492
186
100
mA
XC5VLX85T
515
196
100
mA
Table 5: Power-On Current for Virtex-5 Devices
Device
ICCINTMIN ICCAUXMIN
Typ(1)
Typ(1)
ICCOMIN
Typ(1)
Units
XC5VLX110
623
250
100
mA
XC5VLX110T
651
260
100
mA
XC5VLX155
695
351
100
mA
XC5VLX155T
728
368
100
mA
XC5VLX220
1023
458
150
mA
XC5VLX220T
1056
472
150
mA
XC5VLX330
1470
690
150
mA
XC5VLX330T
1509
706
150
mA
XC5VSX35T
307
98
50
mA
XC5VSX50T
472
148
50
mA
XC5VSX95T
804
262
100
mA
XC5VSX240T
1632
662
150
mA
XC5VTX150T
969
386
150
mA
XC5VTX240T
1245
572
150
mA
XC5VFX30T
358
116
50
mA
XC5VFX70T
695
232
100
mA
XC5VFX100T
749
298
100
mA
XC5VFX130T
1111
392
150
mA
XC5VFX200T
1222
534
150
mA
Notes:
1. Typical values are specified at nominal voltage, 25°C.
2. The maximum startup current can be obtained using the
XPOWER Estimator (XPE) or XPOWER Analyzer (XPA) tools
and adding the quiescent plus dynamic current consumption.
Table 6: Power Supply Ramp Time
Symbol
Description
VCCINT
VCCO
VCCAUX
Internal supply voltage relative to GND
Output drivers supply voltage relative to GND
Auxiliary supply voltage relative to GND
Ramp Time
0.20 to 50.0
0.20 to 50.0
0.20 to 50.0
Units
ms
ms
ms
DS202 (v5.3) May 5, 2010
www.xilinx.com
Product Specification
6