English
Language : 

DS90UB921-Q1 Datasheet, PDF (6/57 Pages) Texas Instruments – 5 - 96 MHz 24-bit Color FPD-Link III Serializer with Bidirectional Control Channel
DS90UB921-Q1
SNLS488 – MARCH 2016
www.ti.com
6 Specifications
6.1 Absolute Maximum Ratings
over operating free-air temperature range (unless otherwise noted)(1)(2)
Supply voltage – VDD33
Supply voltage – VDDIO
LVCMOS I/O voltage
Serializer output voltage - DOUT±
Junction temperature
Storage temperature, Tstg
MIN
MAX
–0.3
4
–0.3
4
–0.3
VDDIO + 0.3
–0.3
2.75
150
–65
150
UNIT
V
V
V
V
°C
°C
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended
Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) If Military/Aerospace specified devices are required, please contact the Texas Instruments Sales Office/ Distributors for availability and
specifications.
6.2 ESD Ratings - JEDEC
V(ESD)
Electrostatic discharge
Human-body model (HBM), per AEC Q100-002(1)
Charged-device model (CDM), per AEC Q100-011
VALUE
±8000
±1500
(1) AEC Q100-002 indicates that HBM stressing shall be in accordance with the ANSI/ESDA/JEDEC JS-001 specification.
UNIT
V
6.3 ESD Ratings—IEC and ISO
V(ESD)
Electrostatic discharge
RD = 330 Ω, CS = 150 pF
RD = 330 Ω, CS = 150 and 330 pF
RD = 2 kΩ, CS = 150 and 330 pF
IEC, powered-up only contact discharge
(DOUT+, DOUT-)
IEC, powered-up only air-gap discharge
(DOUT+, DOUT-)
ISO10605 contact discharge (DOUT+,
DOUT-)
ISO10605 air-gap discharge (DOUT+,
DOUT-)
ISO10605 contact discharge (DOUT+,
DOUT-)
ISO10605 air-gap discharge (DOUT+,
DOUT-)
VALUE
±8000
±18000
±8000
±18000
±8000
±18000
UNIT
V
V
V
6.4 Recommended Operating Conditions
MIN
Supply voltage (VDD33)
3
LVCMOS supply voltage (VDDIO)
3
1.71
Operating free-air temperature (TA)
−40
PCLK frequency, Coax operation, high frequency mode(1)
48
PCLK frequency, Coax operation, intermediate frequency mode(1)
24
PCLK frequency, Coax operation, low frequency mode(1)
15
PCLK frequency, STP operation, high frequency mode(1)
15
PCLK frequency, STP operation, low frequency mode(1)
5
Supply noise -- (DC-50MHz)
(1) For configuration of cable type and frequency mode, refer to Frequency Mode Optimizations.
NOM
3.3
3.3
1.8
25
MAX
3.6
3.6
1.89
105
96
48
24
96
15
100
UNIT
V
V
V
°C
MHz
MHz
MHz
MHz
MHz
mVP-P
6
Submit Documentation Feedback
Product Folder Links: DS90UB921-Q1
Copyright © 2016, Texas Instruments Incorporated