English
Language : 

TCA5013 Datasheet, PDF (11/68 Pages) Texas Instruments – Feature Rich Smartcard Interface IC
www.ti.com
TCA5013
SCPS253B – JANUARY 2014 – REVISED JANUARY 2016
6.16 Electrical Characteristics—SDA and SCL
VDD = VDDI = 3.3 V; LVDD = 10 µH; CVDD = 10 µF; CVUP = 10 µF; TA = –40°C to 85°C unless otherwise noted
PARAMETER
TEST CONDITION
MIN
TYP
ILEAK - SDA, SCL
VOL - SDA, SCL
IOL - SDA, SCL
VIL - SDA, SCL
VIH - SDA, SCL
Input leakage current
SDA output low voltage
SDA max output low current
Input low signal
Input high signal
Voltage on pin = VDDI
IOL = -3 mA
VOL = 0.3 V
0.8 VDDI
MAX
1
0.1 VDDI
10
0.2 VDDI
UNIT
µA
V
mA
V
V
6.17 Electrical Characteristics—Fault Condition Detection
VDD = VDDI = 3.3 V; LVDD = 10 µH; CVDD = 10 µF; CVUP = 10 µF; TA = –40°C to 85°C unless otherwise noted
PARAMETER
TEST CONDITION
MIN
TYP
MAX UNIT
TSD
Shutdown temperature
ISD
Shutdown current
On card VCC pins
On card IO pins
125
160
200
–15
145
°C
260
mA
15
mA
ILIM
Output current limit
On card CLK pins
On card RST pins
–70
70
mA
–20
20
mA
6.18 I2C Interface Timing Requirements(1)
PARAMETER
STANDARD MODE
I2C BUS
MIN
MAX
fscl
I2C clock frequency
tsch
I2C clock high time
tscl
I2C clock low time
tsp
I2C spike time
tsds
I2C serial data setup time
tsdh
I2C serial data hold time
ticr
I2C input rise time
ticf
I2C input fall time
tocf
I2C output fall time; 10 pF to 400 pF bus
tbuf
I2C bus free time between Stop and Start
tsts
I2C Start or repeater start condition setup time
tsth
I2C Start or repeater start condition hold time
tsps
I2C Stop condition setup time
100
4
4.7
50
250
0
1000
300
300
4.7
4.7
4
4
(1) Refer to the Parameter Measurement Information section for more information.
FAST MODE
I2C BUS
MIN MAX
400
0.6
1.3
50
100
0
300
300
300
1.3
0.6
0.6
0.6
FAST MODE PLUS
(FM+) I2C BUS
MIN
MAX
1000
0.26
0.5
50
50
0
120
120
120
0.5
0.26
0.26
0.26
UNIT
kHz
μs
μs
ns
ns
ns
ns
ns
μs
μs
μs
μs
μs
6.19 I2C Interface Timing Characteristics(1)
tvd(data)
tvd(ack)
PARAMETER
Valid data time; SCL low to SDA output valid
Valid data time of ACK condition; ACK signal from SCL low to SDA (out) low
(1) Refer to Parameter Measurement Information section for more information.
MIN
TYP
MAX UNIT
450 ns
450 ns
Copyright © 2014–2016, Texas Instruments Incorporated
Product Folder Links: TCA5013
Submit Documentation Feedback
11