English
Language : 

LM3S6952 Datasheet, PDF (78/626 Pages) Texas Instruments – Stellaris LM3S6952 Microcontroller
System Control
Caution – If the Cortex-M3 Debug Access Port (DAP) has been enabled, and the device wakes from a
low power sleep or deep-sleep mode, the core may start executing code before all clocks to peripherals
have been restored to their run mode configuration. The DAP is usually enabled by software tools
accessing the JTAG or SWD interface when debugging or flash programming. If this condition occurs,
a Hard Fault is triggered when software accesses a peripheral with an invalid clock.
A software delay loop can be used at the beginning of the interrupt routine that is used to wake up a
system from a WFI (Wait For Interrupt) instruction. This stalls the execution of any code that accesses
a peripheral register that might cause a fault. This loop can be removed for production software as the
DAP is most likely not enabled during normal execution.
Because the DAP is disabled by default (power on reset), the user can also power-cycle the device. The
DAP is not enabled unless it is enabled through the JTAG or SWD interface.
6.2 Initialization and Configuration
The PLL is configured using direct register writes to the RCC/RCC2 register. If the RCC2 register
is being used, the USERCC2 bit must be set and the appropriate RCC2 bit/field is used. The steps
required to successfully change the PLL-based system clock are:
1. Bypass the PLL and system clock divider by setting the BYPASS bit and clearing the USESYS
bit in the RCC register. This configures the system to run off a “raw” clock source and allows
for the new PLL configuration to be validated before switching the system clock to the PLL.
2. Select the crystal value (XTAL) and oscillator source (OSCSRC), and clear the PWRDN bit in
RCC/RCC2. Setting the XTAL field automatically pulls valid PLL configuration data for the
appropriate crystal, and clearing the PWRDN bit powers and enables the PLL and its output.
3. Select the desired system divider (SYSDIV) in RCC/RCC2 and set the USESYS bit in RCC. The
SYSDIV field determines the system frequency for the microcontroller.
4. Wait for the PLL to lock by polling the PLLLRIS bit in the Raw Interrupt Status (RIS) register.
5. Enable use of the PLL by clearing the BYPASS bit in RCC/RCC2.
6.3 Register Map
Table 6-1 on page 78 lists the System Control registers, grouped by function. The offset listed is a
hexadecimal increment to the register's address, relative to the System Control base address of
0x400F.E000.
Note: Spaces in the System Control register space that are not used are reserved for future or
internal use. Software should not modify any reserved memory address.
Table 6-1. System Control Register Map
Offset Name
Type
Reset
Description
0x000
0x004
0x008
0x010
DID0
DID1
DC0
DC1
RO
-
Device Identification 0
RO
-
Device Identification 1
RO
0x00FF.007F Device Capabilities 0
RO
0x0011.32FF Device Capabilities 1
See
page
80
97
99
100
78
April 05, 2010
Texas Instruments-Production Data