TL16C750 Datasheet, PDF (4/35 Pages) Texas Instruments – ASYNCHRONOUS COMMUNICATIONS ELEMENT WITH 64-BYTE FIFOs AND AUTOFLOW CONTROL
TL16C750
ASYNCHRONOUS COMMUNICATIONS ELEMENT
WITH 64-BYTE FIFOs AND AUTOFLOW CONTROL
SLLS191C – JANUARY 1995 – REVISED DECEMBER 1997
Terminal Functions
TERMINAL
NAME
NO. NO. I/O
FN PM
DESCRIPTION
A0
31 20 I Register select. A0 – A2 are used during read and write operations to select the ACE register to read from
A1
30 18
or write to. Refer to Table 1 for register addresses and ADS signal description.
A2
29 17
ADS
28 15
I Address strobe. When ADS is active (low), the register select signals (A0, A1, and A2) and chip select signals
(CS0, CS1, CS2) drive the internal select logic directly; when ADS is high, the register select and chip select
signals are held at the logic levels they were in when the low-to-high transition of ADS occurred.
BAUDOUT
17 64 O Baud out. BAUDOUT is a 16 × clock signal for the transmitter section of the ACE. The clock rate is established
by the reference oscillator frequency divided by a divisor specified by the baud generator divisor latches.
BAUDOUT can also be used for the receiver section by tying this output to RCLK.
CS0
14 59 I Chip select. When CS0 and CS1 are high and CS2 is low, the ACE is selected. When any of these inputs
CS1
15 61
are inactive, the ACE remains inactive. Refer to the ADS signal description.
CS2
16 62
CTS
40 33
I Clear to send. CTS is a modem status signal. Its condition can be checked by reading bit 4 (CTS) of the
modem status register. Bit 0 (∆CTS) of the modem status register indicates that CTS has changed states
since the last read from the modem status register. When the modem status interrupt is enabled, CTS
changes states, and the auto-CTS mode is not enabled, an interrupt is generated. CTS is also used in the
auto-CTS mode to control the transmitter.
D0
2 42 I/O Data bus. Eight data lines with 3-state outputs provide a bidirectional path for data, control, and status
D1
3 43
information between the ACE and the CPU. As inputs, they use fail safe CMOS compatible input buffers.
D2
4 45
D3
5 46
D4
6 48
D5
7 50
D6
8 51
D7
9 52
DCD
42 36
I Data carrier detect. DCD is a modem status signal. Its condition can be checked by reading bit 7 (DCD) of
the modem status register. Bit 3 (∆DCD) of the modem status register indicates that DCD has changed states
since the last read from the modem status register. When the modem status interrupt is enabled and DCD
changes state, an interrupt is generated.
DDIS
26 12 O Driver disable. DDIS is active (high) when the CPU is not reading data. When active, DDIS can disable an
external transceiver.
DSR
41 35
I Data set ready. DSR is a modem status signal. Its condition can be checked by reading bit 5 (DSR) of the
modem status register. Bit 1 (∆DSR) of the modem status register indicates DSR has changed states since
the last read from the modem status register. When the modem status interrupt is enabled and the DSR
changes states, an interrupt is generated.
DTR
37 28 O Data terminal ready. When active (low), DTR informs a modem or data set that the ACE is ready to establish
communication. DTR is placed in the active state by setting the DTR bit of the modem control register to one.
DTR is placed in the inactive condition either as a result of a master reset, during loop mode operation, or
clearing the DTR bit.
INTRPT
33 23 O Interrupt. When active (high), INTRPT informs the CPU that the ACE has an interrupt to be serviced. Four
conditions that cause an interrupt to be issued are: a receiver error, received data that is available or timed
out (FIFO mode only), an empty transmitter holding register, or an enabled modem status interrupt. INTRPT
is reset (deactivated) either when the interrupt is serviced or as a result of a master reset.
MR
39 32 I Master reset. When active (high), MR clears most ACE registers and sets the levels of various output signals
(refer to Table 2).
OUT1
OUT2
38 30 O Outputs 1 and 2. These are user-designated output terminals that are set to their active (low) level by setting
35 25
their respective modem control register (MCR) bits (OUT1 and OUT2). OUT1 and OUT2 are set to their
inactive (high) level as a result of master reset, during loop mode operations, or by clearing bit 2 (OUT1) or
bit 3 (OUT2) of the MCR.
RCLK
10 54 I Receiver clock. RCLK is the 16× baud rate clock for the receiver section of the ACE.
4