TL16C750 Datasheet, PDF (10/35 Pages) Texas Instruments – ASYNCHRONOUS COMMUNICATIONS ELEMENT WITH 64-BYTE FIFOs AND AUTOFLOW CONTROL | |||
|
◁ |
TL16C750
ASYNCHRONOUS COMMUNICATIONS ELEMENT
WITH 64-BYTE FIFOs AND AUTOFLOW CONTROL
SLLS191C â JANUARY 1995 â REVISED DECEMBER 1997
system timing requirements over recommended ranges of supply voltage and operating free-air
temperature
PARAMETER
tcR Cycle time, read (tw7 + td8 + td9)
tcW Cycle time, write (tw6 + td5 + td6)
tw1 Pulse duration, clock (XIN) high
tw2 Pulse duration, clock (XIN) low
tw5 Pulse duration, ADS low
tw6 Pulse duration, write strobe
tw7 Pulse duration, read strobe
tw8 Pulse duration, MR
tsu1 Setup time, address valid before ADSâ
tsu2 Setup time, CS valid before ADSâ
tsu3 Setup time, data valid before WR1â or WR2â
tsu4â Setup time, CTSâ before midpoint of stop bit
th1 Hold time, address low after ADSâ
th2 Hold time, CS valid after ADSâ
th3 Hold time, CS valid after WR1â or WR2â
th4â Hold time, address valid after WR1â or WR2â
th5 Hold time, data valid after WR1â or WR2â
th6 Hold time, CS valid after RD1â or RD2â
th7â Hold time, address valid after RD1â or RD2â
td4â Delay time, CS valid before WR1â or WR2â
td5 Delay time, address valid before WR1â or WR2â
td6â Delay time, write cycle, WR1â or WR2â to ADSâ
td7â Delay time, CS valid to RD1â or RD2â
td8â Delay time, address valid to RD1â or RD2â
td9 Delay time, read cycle, RD1â or RD2â to ADSâ
td10 Delay time, RD1â or RD2â to data valid
td11 Delay time, RD1â or RD2â to floating data
â Only applies when ADS is low
ALT. SYMBOL
RC
WC
tXH
tXL
tADS
tWR
tRD
tMR
tAS
tCS
tDS
tAH
tCH
tWCS
tWA
tDH
tRCS
tRA
tCSW
tAW
tWC
tCSR
tAR
tRC
tRVD
tHZ
FIGURE
4
4
5, 6
5
6
5, 6
5, 6
5
16
5, 6
5, 6
5
5
5
6
6
5
5
5
6
6
6
6
6
TEST CONDITIONS
f = 16 MHz maximum
f = 16 MHz maximum
CL = 75 pF
CL = 75 pF
MIN MAX UNIT
87
ns
87
ns
25
ns
25
ns
9
ns
40
ns
40
ns
1
µs
8
ns
8
ns
15
ns
10 ns
0
ns
0
ns
10
ns
10
ns
5
ns
10
ns
20
ns
7
ns
7
ns
40
ns
7
ns
7
ns
40
ns
45
ns
20
ns
system switching characteristics over recommended ranges of supply voltage and operating
free-air temperature (see Note 9)
PARAMETER
ALT. SYMBOL FIGURE TEST CONDITIONS
tdis(R) Disable time, RD1ââ or RD2ââ to DDISââ
tRDD
6
CL = 75 pF
NOTE 9: Charge and discharge times are determined by VOL, VOH, and external loading.
MIN MAX UNIT
20
ns
baud generator switching characteristics over recommended ranges of supply voltage and
operating free-air temperature, CL = 75 pF
PARAMETER
ALT. SYMBOL FIGURE TEST CONDITIONS MIN MAX UNIT
tw3
Pulse duration, BAUDOUT low
tw4
Pulse duration, BAUDOUT high
td1
Delay time, XINâ to BAUDOUTâ
td2
Delay time, XINââ to BAUDOUTâ
tLW
tHW
tBLD
tBHD
4
f = 16 MHz, CLK ÷ 2
4
f = 16 MHz, CLK ÷ 2
4
4
50
ns
50
ns
45 ns
45 ns
10