English
Language : 

C541U_99 Datasheet, PDF (78/192 Pages) Siemens Semiconductor Group – 8-BIT CMOS MICROCONTROLLER
On-Chip Peripheral Components
C541U
Special Function Register STB (Address 94H)
Special Function Register SRB (Address 95H)
Reset Value : XXH
Reset Value : XXH
MSB
LSB
Bit No. 7
6
5
4
3
2
1
0
94H
.7
.6
.5
.4
.3
.2
.1
.0 STB
95H
.7
.6
.5
.4
.3
.2
.1
.0 SRB
After reset the contents of the shift register and the receive buffer register are undefined.
The register SSCMOD is used to enable test modes during factory test. It must not be written or
modified during normal operation of the C541U.
Special Function Register SSCMOD (Address 96H)
MSB
Bit No. 7
6
5
4
3
2
96H LOOPB TRIO 0
0
0
0
Reset Value : 00H
LSB
1
0
0 LSBSM SSCMOD
Bit
LOOPB
TRIO
5-1
LSBSM
Function
SSC loopback enable
This bit should be used for test purposes only.
LOOPB = 0 : The SSC operates as specified.
LOOPB = 1 : The STO output is connected internally via an inverter to the
SRI input, allowing to check the transfer locally without a second
SSC device.
SSC disable tristate mode of SSC inputs
This bit should be used for test purposes only.
TRIO = 0 : The SSC operates as specified.
TRIO = 1 : The SSC inputs will be connected to the output latch of the
corresponding port pin. This allows a test of the SSC in slave
mode by simulating a transfer via a program setting the port
latches accordingly.
All bits of this register are set to 0 after reset. When writing SSCMOD, these
bits must be written with 0.
SSC LSB shift mode
If LSBSM is cleared, the SSC will shift out the MSB of the data first LSB last. If
LSBSM is set, the SSC will shift out LSB first and MSB last.
Semiconductor Group
6-33
1999-04-01