Reset / System Clock
C541U
After a hardware reset operation bits PCLK, SPEED, and UCLK are set to 0. Depending on the
required operating mode of the USB module a well defined procedure must be executed for
switching on the clock for the USB module :
– Full speed mode
USB PLL is switched on by setting bit PCLK
waiting 3 ms for PLL being locked
setting bit UCLK
– Low speed mode setting bit UCLK only
The switch-on procedure after hardware reset assures a proper operation of the USB clock system.
A software reset operation of the USB module must follow this clock system switch-on procedure.
Details of the software reset operation are described in chapter 6.4.5 on page 6-51.
XTAL1 and XTAL2 are the input and output of a single-stage on-chip inverter which can be
configured with off-chip components as a Pierce oscillator. The oscillator, in any case, drives the
internal clock generator. The clock generator provides the internal clock signals to the chip. These
signals define the internal phases, states and machine cycles.
Figure 5-5 shows the recommended oscillator circuit.
C
XTAL2
12
C541U
C
MHz
XTAL1
C = 20pF ± 10pF for crystal operation
Figure 5-5
Recommended Crystal Oscillator Circuit
In this application the on-chip oscillator is used as a crystal-controlled, positive-reactance oscillator
(a more detailed schematic is given in figure 5-6). lt operates in fundamental response mode as an
inductive reactor in parallel resonance with a capacitor external to the chip. The crystal
specifications and capacitances are non-critical. In this circuit 20 pF can be used as single
capacitance at any frequency together with a good quality crystal.
Semiconductor Group
5-7