2. Electrical Characteristics
Table 2.25 Timing of recovery from low power modes (3)
Parameter
Recovery time
from Software
Standby mode*1
Low-speed
mode
Test
Symbol Min Typ Max Unit conditions
Crystal
resonator
connected to
main clock
oscillator
System clock source is tSBYMC -
main clock oscillator
(1 MHz)*2
2
3
ms Figure 2.31
External clock
input to main
System clock source is tSBYEX -
main clock oscillator
clock oscillator (1 MHz)*3
28 50 μs
System clock source is MOCO (1 MHz)
tSBYMO -
25 35 μs
Note 1. The division ratio of ICK and PCKx is the minimum division ratio within the allowable frequency range. The
recovery time is determined by the system clock source.
Note 2. The Main Clock Oscillator Wait Control Register (MOSCWTCR) is set to 05h.
Note 3. The Main Clock Oscillator Wait Control Register (MOSCWTCR) is set to 00h.
Table 2.26 Timing of recovery from low power modes (4)
Parameter
Symbol Min Typ
Recovery time
from Software
Low-voltage Crystal
mode
resonator
System clock source is tSBYMC -
2
main clock oscillator
Standby mode*1
connected to (4 MHz)*2
main clock
oscillator
External clock System clock source is tSBYEX -
108
input to main main clock oscillator
clock oscillator (4 MHz)*3
System clock source is HOCO (4 MHz)
tSBYHO -
108
Test
Max Unit conditions
3
ms Figure 2.31
130 μs
130 μs
Note 1. The division ratio of ICK and PCKx is the minimum division ratio within the allowable frequency range. The
recovery time is determined by the system clock source.
Note 2. The Main Clock Oscillator Wait Control Register (MOSCWTCR) is set to 05h.
Note 3. The Main Clock Oscillator Wait Control Register (MOSCWTCR) is set to 00h.
Table 2.27 Timing of recovery from low power modes (5)
Parameter
Recovery time
from Software
Standby mode*1
SubOSC-speed mode
System clock source is sub-clock
oscillator (32.768 kHz)
System clock source is LOCO
(32.768 kHz)
Symbol Min
tSBYSC -
tSBYLO -
Typ Max
0.85 1
0.85 1.2
Test
Unit conditions
ms Figure 2.31
ms
Note 1. The sub-clock oscillator or LOCO itself continues oscillating in Software Standby mode during Subosc-speed
mode.