English
Language : 

TLE9263-3QX Datasheet, PDF (58/198 Pages) Infineon Technologies AG – Dedicated Data Sheets are available for the different product variants
6.3
Electrical Characteristics
TLE9263-3QX
Voltage Regulator 1
Table 16 Electrical Characteristics
VS = 5.5 V to 28 V; Tj = -40 °C to +150 °C; all voltages with respect to ground, positive current flowing into pin
(unless otherwise specified)
Parameter
Symbol
Values
Unit Note / Test Condition Number
Output Voltage including line VCC1,out1
and Load regulation
Min. Typ. Max.
4.9 5.0 5.1 V
Output Voltage including line
and Load regulation
Output Voltage including line
and Load regulation
VCC1,out2
VCC1,out3
4.9 5.0
4.97 –
5.1 V
5.07 V
1)SBC Normal Mode;
10µA < IVCC1 < 250mA
6V < VS < 28V
1)SBC Normal Mode;
10µA < IVCC1 < 150mA
1)2)SBC Normal Mode;
20mA < IVCC1 < 90mA
8V < VS < 18V
25°C < Tj < 125°C
P_6.3.1
P_6.3.7
P_6.3.12
Output Voltage including line VCC1,out41 4.9 5.05 5.2 V
and Load regulation
SBC Stop Mode;
P_6.3.2
1mA < IVCC1 < IVCC1,Ipeak
Output Voltage including line VCC1,out42 4.9
and Load regulation
5.05 5.25 V
SBC Stop Mode;
10µA < IVCC1 < 1mA
P_6.3.20
Output Drop
VCC1,d1
–
–
500 mV IVCC1 = 50mA
VS=3V
P_6.3.3
Output Drop
VCC1,d2
–
VCC1 Active Peak Threshold 1 IVCC1,Ipeak1,r –
(Transition threshold between
low-power and high-power
mode regulator)
–
500 mV IVCC1 = 150mA
VS=5V
1.9 3.5
mA 2) ICC1 rising;
VS = 13.5V
-40°C < Tj < 150°C;
I_PEAK_TH = ‘0’
P_6.3.4
P_6.3.13
VCC1 Active Peak Threshold 1 IVCC1,Ipeak1,f 0.5 1.3 –
(Transition threshold between
high-power and low-power
mode regulator)
mA 2) ICC1 falling;
VS = 13.5V
-40°C < Tj < 150°C;
I_PEAK_TH = ‘0’
P_6.3.17
VCC1 Active Peak Threshold 2 IVCC1,Ipeak2,r –
(Transition threshold between
low-power and high-power
mode regulator)
4.3 7.0
mA 2) ICC1 rising;
VS = 13.5V
-40°C < Tj < 150°C;
I_PEAK_TH = ‘1’
P_6.3.18
VCC1 Active Peak Threshold 2 IVCC1,Ipeak2,f 1.7 3.4 –
(Transition threshold between
high-power and low-power
mode regulator)
mA 2) ICC1 falling;
VS = 13.5V
-40°C < Tj < 150°C;
I_PEAK_TH = ‘1’
P_6.3.19
Over Current Limitation
IVCC1,lim
250 –
12002) mA current flowing out of P_6.3.6
pin, VCC1 = 0V
1)In SBC Stop Mode, the specified output voltage tolerance applies when IVCC1 has exceeded the selected active
peak threshold I( VCC1,Ipeak1,r or IVCC1,Ipeak2,r) but with increased current consumption.
2) Not subject to production test, specified by design.
Data Sheet
58
Rev. 1.1, 2014-09-26