English
Language : 

TLE9263-3QX Datasheet, PDF (21/198 Pages) Infineon Technologies AG – Dedicated Data Sheets are available for the different product variants
TLE9263-3QX
General Product Characteristics
6) No pull-up or pull-down configuration selected.
7) The specified WKx current consumption adder for wake capability applies regardless how many WK inputs are activated.
8) A typ. 75µA / max 125µA (Tj = 85°C) adder applies for every additionally activated HSx switch in SBC Stop Mode;
In SBC Normal Mode every HSx switch consumes the typ. 75µA / max 125µA (Tj = 85°C) without the initial adder because
the biasing is already enabled.
9) HS1 used for cyclic sense, Timer 2, 20ms period, 0.1ms on-time, no load on HS1.
In general the current consumption adder for cyclic sense in SBC Stop Mode can be calculated with below equation:
IStop,CS = 18µA + (525µA *tON/TPer)
10) Also applies to Cyclic Wake
Note: There is no additional current consumption contribution due to PWM generators.
Data Sheet
21
Rev. 1.1, 2014-09-26