English
Language : 

MB84VD23381FJ Datasheet, PDF (35/54 Pages) Fujitsu Component Limited. – Stacked MCP (Multi-Chip Package) FLASH MEMORY & FCRAM
MB84VD23381FJ-80
s 64 M FCRAM AC Charactaristics for MCP
• READ OPERATION (FCRAM)
Parameter
Read Cycle Time
Chip Enable Access Time
Output Enable Access Time
Chip Enable Access Time
Output Data Hold Time
CE1r Low to Output Low-Z
OE Low to Output Low-Z
CE1r High to Output High-Z
OE High to Output High-Z
Address Setup Time to CE1r Low
Address Setup Time to OE
Address Invalid Time
CE1r Low to Address Hold Time
OE Low to Address Hold Time
CE1r High to Address Hold Time
OE High to Address Hold Time
CE1r Low to OE Low Delay Time
OE Low to CE1r High Delay Time
CE1r High Pulse Width
OE High Pulse Width
Symbol
tRC
tCE
tOE
tAA
tOH
tCLZ
tOLZ
tCHZ
tOHZ
tASC
tASO
tASO[ABS]
tAX
tCLAH
tOLAH
tCHAH
tOHAH
tCLOL
tOLCH
tCP
tOP
tOP[ABS]
Value
Min
Max
90


80

45

80
5

5

0


30

25
−5

45

10


5
90

45

−5

–5

45
1000
45

20

45
1000
20

Unit
Notes
ns
ns
*1, *3
ns
*1
ns
*1, *4
ns
*1
ns
*2
ns
*2
ns
*2
ns
*2
ns
*5
ns
*3, *6
ns
*7
ns
*4
ns
*4
ns
*4, *8
ns
ns
ns *4, *6, *8, *9
ns
*8
ns
ns
*6, *8, *9
ns
*7
*1: The output load is 30 pF.
*2: The output load is 5 pF.
*3: The tCE is applicable if OE is brought to Low before CE1r goes Low and is also applicable if actual value of both
or either tASO or tCLOL is shorter than specified value.
*4: Applicable only to A0 and A1 when both CE1r and OE are kept at Low for the address access.
*5: Applicable if OE is brought to Low before CE1r goes Low.
*6: The tASO, tCLOL (Min) and tOP (Min) are reference values when the access time is determined by tOE.
If actual value of each parameter is shorter than specified minimum value, tOE becomes longer by the amount
of subtracting actual value from specified minimum value.
For example, if actual tASO, tASO (actual) , is shorter than specified minimum value, tASO (Min) , during OE control
access (i.e., CE1r stays Low) , the tOE becomes tOE (Max) + tASO (Min) − tASO (actual) .
*7: The tASO[ABS] and tOP[ABS] are the absolute minimum values during OE control access.
*8: If actual value of either tCLOL or tOP is shorter than specified minimum value, both tOLAH and tOLCH become tRC (Min)
− tCLOL (actual) or tRC (Min) − tOP (actual) .
*9: Maximum value is applicable if CE1r is kept at Low.
34