s ELECTRICAL CHARACTERISTICS
1. DC Characteristics
(VDD = +5 V±5%, VSS = 0 V, Ta = 0°C to +70°C)
Parameter
Symbol
Condition
Value
Unit
Min. Max.
CLK
3.5 — V
“H” level
input voltage
Except SCSI and
CLK pins
VIH
—
2.2 — V
SCSI pins
2.0 — V
“L” level
input voltage
CLK
Except CLK pin
VIL
— 1.5 V
—
— 0.8 V
Input hysteresis of SCSI pins *1
VHW
—
0.3 — V
Except SCSI pins
IOH = –2.0 mA
“H” level
output voltage *1
SCSI Three-state
VOH IOH = –8.0 mA
pins Open-drain
—
4.2 VDD V
2.0 — V
—— V
“L” level
Except SCSI pins
output voltage *1 SCSI pins
IOL = +3.2 mA
VOL
IOL = +48.0 mA
VSS 0.4 V
— 0.5 V
Input leakage current
ILI VSS ≤ VI ≤ VDD
–10 +10 µA
Input/output leakage current
ILOZ VSS ≤ VI ≤ VDD, See Note below
–10 +10 µA
CLK input = 20 MHz
SPC operating clock = 10 MHz
45 mA
CLK input = 30 MHz
SPC operating clock = 10 MHz
48 mA
Power supply current
CLK input = 40 MHz
All output SPC operating clock = 13.3 MHz
55 mA
IDD pins
—
opened
CLK input = 30 MHz
SPC operating clock = 15 MHz
65 mA
CLK input = 20 MHz
SPC operating clock = 20 MHz
60 mA
CLK input = 40 MHz
SPC operating clock = 20 MHz
70 mA
*1: SCSI pins are DB7 to DB0, DBP, BSY, SEL, RST, ATN, REQ, ACK, MSG, C/D, I/O
Note: Leakage current in the above spec indicates the following currents.
(1) Leakage current at the high-Z state on the three-state output pins.
(2) Leakage current at the output high-Z state (input state) on the bidirectional bus pins.
12