English
Language : 

PXR40 Datasheet, PDF (66/100 Pages) Freescale Semiconductor, Inc – PXR40 Microcontroller
Electrical characteristics
Table 14. DSPI LVDS pad specification (continued)
9 Diff Skew Itphla-tplhbI or
Itplhb-tphlaI
TSKEW
—
—
—
Termination
10 Trans. Line (differential Zo)
—
11 Temperature
—
—
95
100
—
–40
—
0.5
ns
105
ohms
150
C
5.8 Oscillator and FMPLL electrical characteristics
Table 15. FMPLL Electrical Specifications1
(VDDSYN = 3.0 V to 3.6 V, VSS = VSSSYN = 0 V, TA = TL to TH)
Spec
Characteristic
Symbol
Min
Max
Unit
1 PLL Reference Frequency Range2 (Normal Mode)
Crystal Reference (PLLCFG2 = 0b0)
Crystal Reference (PLLCFG2 = 0b1)
External Reference (PLLCFG2 = 0b0)
External Reference (PLLCFG2 = 0b1)
fref_crystal
8
fref_crystal
16
fref_ext
8
fref_ext
16
2 Loss of Reference Frequency4
fLOR
100
3 Self Clocked Mode Frequency5
fSCM
4
4 PLL Lock Time6
tLPLL
—
5 Duty Cycle of Reference 7
tDC
40
20
403
20
40
1000
16
< 400
60
MHz
kHz
MHz
s
%
6 Frequency un-LOCK Range
fUL
–4.0
4.0
% fsys
7 Frequency LOCK Range
8 D_CLKOUT Period Jitter8, 9 Measured at fSYS Max
Cycle-to-cycle Jitter
fLCK
CJitter
–2.0
–5
2.0
% fsys
5
%fclkout
9 Peak-to-Peak Frequency Modulation Range Limit 10,11
(fsys Max must not be exceeded)
10 FM Depth Tolerance12
Cmod
Cmod_err
0
–0.25
4
0.25
%fsys
%fsys
11 VCO Frequency
fVCO
192
600
MHz
12 Modulation Rate Limits13
fmod
0.400
1
MHz
13 Predivider output frequency range14
fprediv
4
10
MHz
1 All values given are initial design targets and subject to change.
2 Crystal and External reference frequency limits depend on device relying on PLL to lock prior to release of reset, default
PREDIV/EPREDIV, MFD/EMFD default settings, and VCO frequency range. Absolute minimum loop frequency is 4 MHz.
3 Upper tolerance of less than 1% is allowed on 40MHz crystal.
4 “Loss of Reference Frequency” is the reference frequency detected internally, which transitions the PLL into self clocked mode.
5 Self clocked mode frequency is the frequency that the PLL operates at when the reference frequency falls below fLOR. This
frequency is measured at D_CLKOUT. A default RFD value of (0x05) is used in SCM mode, and the programmed MFD and
RFD values have no effect
PXR40 Microcontroller Data Sheet, Rev. 1
66