English
Language : 

3UG4622-1AW30 Datasheet, PDF (20/114 Pages) List of Unclassifed Manufacturers – Monitoring and Control Devices
SIMOCODE 3UF Motor Management and Control Devices
SIMOCODE pro 3UF7
motor management and control devices
Current measuring
modules or current/
voltage measuring
modules
Contactors
CLASS 30
CLASS 35
Types
Set current 0.3 ... 3.0 A
3UF7 1 . 0-1AA00-0
3RT10 15
3RT10 16
Set current 2.4 ... 25 A
3UF7 1 . 1-1AA00-0
3RT10 15
3RT10 16
3RT10 17
3RT10 23
3RT10 24
3RT10 25
3RT10 26
3RT10 34
3RT10 35
Set current 10 ... 100 A
3UF7 1 . 2-1AA00-0
3RT10 34
3RT10 35
3RT10 36
3RT10 44
3RT10 45
3RT10 46
3RT10 54
3RT10 55
Set current 20 ... 200 A
3UF7 1 . 3-1 . A00-0
3RT10 54
3RT10 55
3RT10 56
Set current 63 ... 630 A
3UF7 1 . 4-1BA00-0
3RT10 64
3RT10 65
3RT10 66
3RT10 75
3RT10 76
3RT12 64
3RT12 65
3RT12 66
3RT12 75
3RT12 76
3TF683)
3TF693)
Rated operational current Ie/AC-3 in A at ... V
400 V 500 V 690 V 400 V 500 V 690 V
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
7.0
5.0
4.0
7.0
5.0
4.0
9.0
6.5
5.2
9.0
6.5
5.2
9.0
9.0
6.3
9.0
9.0
6.3
--
--
--
--
--
--
12.0 12.0 9.0
12.0 12.0 9.0
14.0 14.0 13.0 13.0 13.0 13.0
14.0 14.0 13.0 13.0 13.0 13.0
19.1 19.1 19.1 17.6 17.6 17.6
25.0 25.0 24.0 25.0 25.0 24.0
19.1 19.1 19.1 17.6 17.6 17.6
26.5 26.5 24.0 25.0 25.0 24.0
26.5 26.5 24.0 25.0 25.0 24.0
41.7 41.7 41.7 38.2 38.2 38.2
45.0 45.0 45.0 43.0 43.0 43.0
50.0 50.0 50.0 47.0 47.0 47.0
69.0 69.0 69.0 63.0 63.0 63.0
90.0 90.0 90.0 82.0 82.0 82.0
69.0 69.0 69.0 64.0 64.0 64.0
90
90
90
82
82
82
111 111 111 102 102 102
135 135 135 126 126 126
159 159 159 146 146 146
180 180 180 165 165 165
240 240 240 220 220 220
300 300 300 275 275 275
173 173 173 152 152 152
204 204 204 180 180 180
231 231 231 204 204 204
316 316 316 --
--
--
385 385 385 340 340 340
376 376 376 344 344 344
500 500 500 469 469 469
1) Note the operational voltage.
2) Assignment and short-circuit protective devices
acc. to IEC 60947-4-1.
Type of coordination "1": Contactors or starters must not endanger
persons or equipment in the event of a short-circuit. They do not have to
be suitable for further operation without repair and the renewal of parts.
Type of coordination "2": Contactors or starters must not endanger
persons or equipment in the event of a short-circuit and must be suitable
for continued use. There is a risk of contact welding.
3) Contactor cannot be mounted.
4) Please ensure that the maximum AC-3 operational current has a sufficient
safety clearance from the rated fuse current.
CLASS 40
400 V 500 V
3.0
3.0
3.0
3.0
7.0
5.0
8.5
6.5
8.5
8.5
--
--
12.0 12.0
12.0 12.0
12.0 12.0
16.1 16.1
23.5 23.5
16.1 16.1
23.5 23.5
23.5 23.5
34.5 34.5
40.0 40.0
44.0 44.0
57.0 57.0
74.0 74.0
--
--
74
74
93
93
--
--
133 133
150 150
200 200
250 250
131 131
156 156
177 177
--
--
316 316
317 317
438 438
690 V
3.0
3.0
4.0
5.2
6.3
--
9.0
12.0
12.0
16.1
23.5
16.1
23.5
23.5
34.5
40.0
44.0
57.0
74.0
--
74
93
--
133
150
200
250
131
156
177
--
316
317
438
Fuse links1)
LV HRC type 3NA
DIAZED type 5SB
NEOZED type 5SE
Operational class gL(gG)
Types of coordination2)
1
2
690 V
690 V
35
20
35
20
35
20
35
20
35
20
63
25
63
25
63
25
100
35
125
63
125
63
125
63
125
63
160
80
200
125
200
160
200
160
355
315
355
315
355
315
355
315
355
315
500
400
500
400
500
400
630
400
630
500
500
500
500
500
500
500
800
800
800
800
800
5004)
800
6304)
7/20
Siemens LV 1 T · 2006