3UG4622-1AW30 Datasheet, PDF (103/114 Pages) List of Unclassifed Manufacturers – Monitoring and Control Devices | |||
|
◁ |
3TK28 Safety Relays
With electronic enabling circuits
â Technical specifications
Type
Standards
3TK28 40
3TK28 41
3TK28 42
3TK28 45
EN 60204-1 (VDE 0113 Part 1), EN ISO 12100, EN 954-1, IEC 61508, DIN VDE 01161)
Category acc. to EN 954-1
3
4
4
4
Test certificates
TÃV, UL, CSA
Rated insulation voltage Ui
⢠For control circuit
V 50
50
50
50
⢠For outputs
V 50
50
50
50/300
Rated impulse withstand voltage Uimp
⢠For control circuit
V 500
500
500
500
⢠For outputs
V 500
500
500
500/2000
Operating range
⢠DC operation
Rated operational currents Ie
acc. to IEC 60947-5-1
0.9 ... 1.15 Ã Us
⢠Ie/AC-15
at 115 V A --
--
--
2
at 230 V A --
--
--
--
⢠Ie/ DC-13
at 24 V A 0.5
1.5
1.5
1.5
Short-circuit protection
Short-circuit proof
Short-circuit proof2)
Electrical endurance
Unlimited, because switched electronically
Operating frequency z
in operating cycles/h during normal duty
1/h 3000
Response time
⢠Monitored start
⢠Autostart
ms 125
60
60
60
ms 250
60
60
60
release time
⢠For EMERGENCY-STOP
⢠For supply failure
ms 30
ms 25
45
1004)
453)/0.05 ... 300 s
(adjustable)
1004)
453)/0.05 ... 300 s
(adjustable)
100
Recovery time
⢠For EMERGENCY-STOP
⢠For supply failure
Bridging of supply failures
ms 20
s 0.02
ms 255)
400
max. 7
254)5)
400
max. 7
254)5)
400
max. 7
255)
Minimum command duration
⢠EMERGENCY-STOP
⢠ON button
ms 20
s 0.02
25
0.2 ... 5
30
0.2 ... 5
30
0.2 ... 5
Simultaneity
ms Â
Conductor cross-sections
Screw-type connection
⢠Finely stranded with end sleeve
⢠Solid
⢠Tightening torque
mm2 2 Ã (0.5 ... 1.5), 1 Ã (0.5 ... 2.5)
mm2 2 Ã (0.5 ... 2.5), 1 Ã (0.5 ... 4)
Nm 0.8 ... 1.2
Spring-loaded terminals
⢠Solid
⢠Finely stranded with end sleeve
⢠Finely stranded without end sleeve
⢠AWG conductors, solid or stranded
(1 or 2 conductors can be connected)
mm2 2 Ã (0.25 ... 1.5)
mm2 2 Ã (0.25 ... 1.0)
mm2 2 Ã (0.25 ... 1.5)
2 Ã AWG 24 ... 16
Permissible ambient temperature
⢠During operation
⢠During storage
°C â25 ... +60
°C â40 ... +80
Degree of protection acc. to EN 60529
⢠Enclosures
⢠Terminals
IP40
IP20
Touch protection acc. to DIN VDE 0106 Part 100
Finger-safe
Shock resistance
⢠Sinewave
g/ms 8/10 and 15/5
Permissible mounting position
Any
1) Electrical equipment for furnaces.
VDE certificate for 3TK28 41 and 3TK28 42 is available.
2) For relay outputs, use a fuse link:
LV HRC Type 3NA, DIAZED Type 5SB, NEOZED Type 5SE:
6 A (weld-free protection at IK = 1 kA).
3) For instantaneous output.
4) When the cascading input is supplied from A1, the maximum response
time is applicable to an external EMERGENCY-STOP.
5) The drivers are not supplied, internal supply bridging only.
SELV/PELV power supply unit buffered.
Siemens LV 1 T · 2006 7/103
|
▷ |