English
Language : 

AM186ED Datasheet, PDF (84/88 Pages) Advanced Micro Devices – High Performance, 80C186- and 80C188-Compatible, 16-Bit Embedded Microcontrollers
PRELIMINARY
SWITCHING CHARACTERISTICS over COMMERCIAL and INDUSTRIAL operating ranges
Reset and Bus Hold (20 MHz and 25 MHz)
Preliminary
Parameter
20 MHz
25 MHz
No. Symbol
Description
Min
Max
Min
Max Unit
Reset and Bus Hold Timing Requirements
5
tCLAV AD Address Valid Delay and BHE
15
tCLAZ AD Address Float Delay
57
tRESIN RES Setup Time
58
tHVCL HOLD Setup(a)
Reset and Bus Hold Timing Responses
0
25
0
20
ns
0
25
0
20
ns
10
10
ns
10
10
ns
62
tCLHAV HLDA Valid Delay
63
tCHCZ Command Lines Float Delay
64
tCHCV Command Lines Valid Delay (after Float)
0
25
0
20
ns
25
20
ns
25
20
ns
SWITCHING CHARACTERISTICS over COMMERCIAL operating ranges
Reset and Bus Hold (33 MHz and 40 MHz)
Preliminary
T No. Symbol
Parameter
Description
33 MHz
Min
Max
40 MHz
Min
Max Unit
Reset and Bus Hold Timing Requirements
5
tCLAV AD Address Valid Delay and BHE
F 15
tCLAZ AD Address Float Delay
57
tRESIN RES Setup Time
58
tHVCL HOLD Setup(a)
Reset and Bus Hold Timing Responses
0
15
0
12
ns
0
15
0
12
ns
8
5
ns
8
5
ns
62
tCLHAV HLDA Valid Delay
A 63
tCHCZ Command Lines Float Delay
64
tCHCV Command Lines Valid Delay (after Float)
0
15
0
12
ns
15
12
ns
15
12
ns
Notes:
All timing parameters are measured at 1.5 V with 50 pF loading on CLKOUTA, unless otherwise noted. All output test conditions
R are with CL =50 pF. For switching tests, VIL=0.45 V and VIH =2.4 V, except at X1 where VIH =VCC – 0.5 V.
D a This timing must be met to guarantee recognition at the next clock.
84