English
Language : 

AM186ED Datasheet, PDF (79/88 Pages) Advanced Micro Devices – High Performance, 80C186- and 80C188-Compatible, 16-Bit Embedded Microcontrollers
PRELIMINARY
SWITCHING CHARACTERISTICS over COMMERCIAL and INDUSTRIAL operating ranges
Clock (20 MHz and 25 MHz)
Preliminary
Parameter
20 MHz
25 MHz
No. Symbol
Description
Min
Max
Min
Max Unit
CLKIN Requirements
36
tCKIN
X1 Period(a)
37
tCLCK X1 Low Time (1.5 V)(a)
38
tCHCK X1 High Time (1.5 V)(a)
39
tCKHL X1 Fall Time (3.5 to 1.0 V)(a)
40
tCKLH X1 Rise Time (1.0 to 3.5 V)(a)
CLKOUT Timing
50
60
40
60
ns
15
15
ns
15
15
ns
5
5
ns
5
5
ns
42
tCLCL CLKOUTA Period
50
40
ns
43
tCLCH CLKOUTA Low Time (CL=50 pF) 0.5tCLCL–2=23
0.5tCLCL – 2 = 18
ns
44
tCHCL CLKOUTA High Time (CL=50 pF) 0.5tCLCL–2=23
0.5tCLCL – 2 = 18
ns
45 tCH1CH2 CLKOUTA Rise Time
(1.0 to 3.5 V)
3
3
ns
46
tCL2CL1 CLKOUTA Fall Time
(3.5 to 1.0 V)
3
3
ns
61
tLOCK Maximum PLL Lock Time
T 69
tCICOA X1 to CLKOUTA Skew
70
tCICOB X1 to CLKOUTB Skew
1
1
ms
15
15
ns
25
25
ns
Notes:
All timing parameters are measured at 1.5 V with 50 pF loading on CLKOUTA, unless otherwise noted. All output test conditions
F are with CL =50 pF. For switching tests, VIL=0.45 V and VIH =2.4 V, except at X1 where VIH =VCC – 0.5 V.
a The specifications for CLKIN are applicable to the normal PLL and CLKDIV2 modes.
The PLL should be used for operations from 16.667 MHz to 40 MHz. For operations below 16.667 MHz, the CLKDIV2
mode should be used.
A Because the CLKDIV2 input frequency is two times the system frequency, the specifications for twice the frequency should
D R be used for CLKDIV2 mode. For example, use the 20 MHz CLKIN specifications for 10 MHz operation.
Am186ED/EDLV Microcontrollers
79