English
Language : 

Z8F1601 Datasheet, PDF (125/246 Pages) Zilog, Inc. – Z8 Encore Microcontrollers with Flash Memory and 10-Bit A/D Converter
Z8F640x/Z8F480x/Z8F320x/Z8F240x/Z8F160x
Z8 Encore!®
107
SPI Control Register
The SPI Control register configures the SPI for transmit and receive operations.
Table 61. SPI Control Register (SPICTL)
BITS
7
6
5
FIELD IRQE
STR
BIRQ
RESET
0
0
0
R/W
R/W
R/W
R/W
ADDR
4
PHASE
3
CLKPOL
0
0
R/W
R/W
F61H
2
WOR
0
R/W
1
MMEN
0
R/W
0
SPIEN
0
R/W
IRQE—Interrupt Request Enable
0 = SPI interrupts are disabled. No interrupt requests are sent to the Interrupt Controller.
1 = SPI interrupts are enabled. Interrupt requests are sent to the Interrupt Controller.
STR—Start an SPI Interrupt Request
0 = No effect.
1 = Setting this bit to 1 also sets the IRQ bit in the SPI Status register to 1. Setting this bit
forces the SPI to send an interrupt request to the Interrupt Control. This bit can be used by
software for a function similar to transmit buffer empty in a UART.
BIRQ—BRG Timer Interrupt Request
If the SPI is enabled, this bit has no effect. If the SPI is disabled:
0 = The Baud Rate Generator timer function is disabled.
1 = The Baud Rate Generator timer function and time-out interrupt are enabled.
PHASE—Phase Select
Sets the phase relationship of the data to the clock. Refer to the SPI Clock Phase and
Polarity Control section for more information on operation of the PHASE bit.
CLKPOL—Clock Polarity
0 = SCK idles Low (0).
1 = SCK idle High (1).
WOR—Wire-OR (Open-Drain) Mode Enabled
0 = SPI signal pins not configured for open-drain.
1 = All four SPI signal pins (SCK, SS, MISO, MOSI) configured for open-drain function.
This setting is typically used for multi-master and/or multi-slave configurations.
MMEN—SPI Master Mode Enable
0 = SPI configured in Slave mode.
1 = SPI configured in Master mode.
PS017610-0404