English
Language : 

W25Q256FVBIF-TR Datasheet, PDF (83/108 Pages) Winbond – 3V 256M-BIT SERIAL FLASH MEMORY WITH DUAL/QUAD SPI & QPI
W25Q256FV
8.2.42 Program Security Registers (42h)
The Program Security Register instruction is similar to the Page Program instruction. It allows from one
byte to 256 bytes of security register data to be programmed at previously erased (FFh) memory
locations. A Write Enable instruction must be executed before the device will accept the Program Security
Register Instruction (Status Register bit WEL= 1). The instruction is initiated by driving the /CS pin low
then shifting the instruction code “42h” followed by a 24/32-bit address (A23/A31-A0) and at least one
data byte, into the DI pin. The /CS pin must be held low for the entire length of the instruction while data is
being sent to the device.
ADDRESS
Security Register #1
Security Register #2
Security Register #3
{A23/A31}-16
00h
00h
00h
A15-12
0001
0010
0011
A11-8
0000
0000
0000
A7-0
Byte Address
Byte Address
Byte Address
The Program Security Register instruction sequence is shown in Figure 46. The Security Register Lock
Bits (LB3-1) in the Status Register-2 can be used to OTP protect the security registers. Once a lock bit is
set to 1, the corresponding security register will be permanently locked, Program Security Register
instruction to that register will be ignored (See 7.1.8, 8.2.25 for detail descriptions).
/CS
CLK
Mode 3
Mode 0
0 1 2 3 4 5 6 7 8 9 10
28 29 30 31 32 33 34 35 36 37 38 39
DI
(IO0)
/CS
* = MSB
Instruction (42h)
24-Bit Address
Data Byte 1
23 22 21
*
321076543210
*
CLK
DI
(IO0)
39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55
Data Byte 2
Data Byte 3
07654321076543210
*
*
Data Byte 256
76543210
*
Mode 3
Mode 0
Figure 46. Program Security Registers Instruction (SPI Mode only)
32-Bit Address is required when the device is operating in 4-Byte Address Mode
- 82 -
Publication Release Date: February 11, 2015
Preliminary – Revision H