W83627THF_06 Datasheet, PDF (75/142 Pages) Winbond – Winbond LPC I/O
W83627THF/W83627THG
Bit 7-4: AUXFANOUT voltage control.
OUTPUT Voltage = AVCC * FANOUT
16
Note: See the Table 5-4
5.8.76 FAN Configuration Register II -- Index 12h (Bank 0)
Register Location:
12h
Power on Default Value
00h
Attribute:
Read/Write
Size:
8 bits
7 6 5 4 32 1 0
Reserved
AUXFANOUT_Mode
AUXFANOUT_Mode
AUXFANOUT_MIN_Volt
CPUFANOUT_MIN_Volt
SYSFANOUT_MIN_Volt
Reserved
Reserved
Bit7-6: Reserved
Bit 5: Set 1, SYSFANOUT voltage will decrease to and keep the value set in Index 08h when
temperature goes below target range. This is to maintain the fan speed in a minimum value.
Set 0, SYSFANOUT duty cycle will decrease to 0 when temperature goes below target range.
Bit 4: Set 1, CPUFANOUT duty cycle will decrease to and keep the value set in Index 09h when
temperature goes below target range. This is to maintain the fan speed in a minimum value.
Set 0, CPUFANOUT duty cycle will decrease to 0 when temperature goes below target range.
Bit 3: Set 1, AUXFANOUT duty cycle will decrease to and keep the value set in Index 15h when
temperature goes below target range. This is to maintain the fan speed in a minimum value.
Set 0, AUXFANOUT duty cycle will decrease to 0 when temperature goes below target range.
Bit2-1: AUXFANOUT mode control.
Set 00, AUXFANOUT is as Manual Mode. (Default).
Set 01, AUXFANOUT is as Thermal Cruise Mode.
Set 10, AUXFANOUT is as Fan Speed Cruise Mode.
Set 11, reserved and no function.
Bit 0:Reserved.
5.8.77 AUXTIN Target Temperature Register/ AUXFANIN Target Speed Register -- Index
13h (Bank 0)
Register Location:
13h
Power on Default Value
00h
- 68 -