5.7 OVT# interrupt mode
The OVT# mode selection bits are at Bank0 Index18h bit4, Bank1 Index52h bit1 and Bank2 Index52h
bit1.
(1) Comparator Mode :
Temperature exceeding TO causes the OVT# output activated until the temperature is less than THYST.
( Figure 5-19)
(2) Interrupt Mode:
Temperature exceeding TO causes the OVT# output activated indefinitely until reset by reading
temperature sensor registers. Temperature exceeding TO, then OVT# reset, and then temperature
going below THYST will also cause the OVT# activated indefinitely until reset by reading temperature
sensor registers. Once the OVT# is activated by exceeding TO , then reset, if the temperature remains
above THYST , the OVT# will not be activated again.( Figure 5-19)
To
THYST
OVT#
(Comparator Mode; default)
OVT#
(Interrupt Mode)
*
*
*
*Interrupt Reset when Temperature sensor registers are read
Figure 5-19