5.6.3 The W83627THF temperature sensor 1(SYSTIN) SMI# interrupt has 3 modes:
(1) Comparator Interrupt Mode
Setting the THYST (Temperature Hysteresis) limit to 127°C will set temperature sensor 1 SMI# to the
Comparator Interrupt Mode. Temperature exceeds TO (Over Temperature) Limit causes an interrupt
and this interrupt will be reset by reading all the Interrupt Status Register. Once an interrupt event has
occurred by exceeding TO, then reset, if the temperature remains above the TO , the interrupt will occur
again when the next conversion has completed. If an interrupt event has occurred by exceeding TO
and not reset, the interrupts will not occur again. The interrupts will continue to occur in this manner
until the temperature goes below TO. (Figure 5-14 ) .
Setting the THYST lower than TO will set temperature sensor 1 SMI# to the Interrupt Mode. The
following are two kinds of interrupt modes, which are selected by Index 4Ch bit5 :
(2) Two-Times Interrupt Mode
Temperature exceeding TO causes an interrupt and then temperature going below THYST will also
cause an interrupt if the previous interrupt has been reset by reading all the interrupt Status Register.
Once an interrupt event has occurred by exceeding TO , then reset, if the temperature remains above
the THYST , the interrupt will not occur. (Figure 5-15 )
(3) One-Time Interrupt Mode
Temperature exceeding TO causes an interrupt and then temperature going below THYST will not cause
an interrupt. Once an interrupt event has occurred by exceeding TO , then going below THYST, an
interrupt will not occur again until the temperature exceeding TO. (Figure 5-16 )
THYST
127'C
TOI
TOI
THYST
SMI#
SMI#
** *
*
*
*Interrupt Reset when Interrupt Status Registers are read
*
*
Figure 5-14
Figure 5-15
- 32 -