16.3 SL RC400 Commands Overview
Command
StartUp
Idle
Transmit
Receive
Transceive
WriteE2
ReadE2
LoadConfig
CalcCRC
Code
Action
Arguments and Data
passed via FIFO
Runs the Reset- and Initialisation
Phase.
3Fhex Note: This command can not be
-
activated by software, but only by a
Power-On or Hard Reset
00hex
No action: cancels current command
execution.
-
1Ah e x
Transmits data from the FIFO buffer to
the label.
Data Stream
Activates Receiver Circuitry.
Note: Before the receiver actually
starts, the state machine waits until the
time configured in the register RcvWait
16hex has passed.
-
Note: This command may be used for
test purposes only, since there is no
timing relation to the Transmit-
Command .
Transmits data from FIFO buffer to the
label and activates automatically the
receiver after transmission.
1Ehex
Note: Before the receiver actually
starts, the SL RC400 waits until the Data Stream
time configured in the register RcvWait
has passed.
Note: This command is the
combination of Transmit and Receive
01hex
Gets data from FIFO buffer and writes
it to the internal E²PROM.
Start Address LSB
Start Address MSB
Data Byte Stream
03hex
Reads data from the internal E²PROM
and puts it into the FIFO buffer.
Start Address LSB
Start Address MSB
Number of Data Bytes
07hex
Reads data from E²PROM and
initialises the SL RC400 registers.
Start Address LSB
Start Address MSB
12hex
Activates the CRC-Coprocessor.
Note: The result of the CRC
calculation can be read from the
registers CRCResultLSB and
CRCResultMSB
Data Byte-Stream
Table 16-1: SL RC400 Command Overview
Returned Data see
via FIFO
Chapter
-
16.3.2
-
16.3.3
-
16.4.1
Data Stream
16.4.2
Data Stream 16.4.3
-
16.5
Data Bytes
16.5.2
-
16.6.1
-
16.5
96