SLRC400 Datasheet, PDF (76/130 Pages) NXP Semiconductors – I·CODE Reader IC | |||
|
◁ |
Philips Semiconductors
Iâ¢CODE Reader IC
Product Specification Rev. 2.0 November 2001
SL RC400
Example:
CoderRate = 0x05 (~52.97kHz)
For Iâ¢CODE1 standard mode the interval should be 8.458ms
->TimeSlotPeriod = CoderRate * interval = 52.97kHz * 8.458ms â1 = 447 (447 = 0x1BF)
Note: The MSB of the TimeSlotPeriod is in the SIGOUTSelect register see 5.2.5.7
Command
Response1
Quit1
Response2
Quit2
TSP1
TSP2
TimeSlotPeriod for TSP1 TimeSlotPeriod for TSP2
Iâ¢CODE1 Standard Mode
0xBF
0x1BF
Iâ¢CODE1 Fast Mode
0x5F
0x67
Note: The MSB of the TimeSlotPeriod is in the SIGOUTSelect register see 5.2.5.7
Note: It is strictly recommended that bit TxCRCEn is set to 0 (see 5.2.5.3) before the Quit-Frame is sent. If
the TxCRCEn is not set to 0 a CRC value is calculated and sent with the Quit-Frame.
To calculate the Quit value a CRC8 algorithm has to be used.
76