Philips Semiconductors
I•CODE Reader IC
Product Specification Rev. 2.0 November 2001
SL RC400
Example:
CoderRate = 0x05 (~52.97kHz)
For I•CODE1 standard mode the interval should be 8.458ms
->TimeSlotPeriod = CoderRate * interval = 52.97kHz * 8.458ms –1 = 447 (447 = 0x1BF)
Note: The MSB of the TimeSlotPeriod is in the SIGOUTSelect register see 5.2.5.7
Command
Response1
Quit1
Response2
Quit2
TSP1
TSP2
TimeSlotPeriod for TSP1 TimeSlotPeriod for TSP2
I•CODE1 Standard Mode
0xBF
0x1BF
I•CODE1 Fast Mode
0x5F
0x67
Note: The MSB of the TimeSlotPeriod is in the SIGOUTSelect register see 5.2.5.7
Note: It is strictly recommended that bit TxCRCEn is set to 0 (see 5.2.5.3) before the Quit-Frame is sent. If
the TxCRCEn is not set to 0 a CRC value is calculated and sent with the Quit-Frame.
To calculate the Quit value a CRC8 algorithm has to be used.
76