English
Language : 

SLRC400 Datasheet, PDF (17/130 Pages) NXP Semiconductors – I·CODE Reader IC
Philips Semiconductors
I•CODE Reader IC
Product Specification Rev. 2.0 November 2001
SL RC400
SL RC400 Register Set (continued)
Page
Addresshex Register Name
Function
20
Page
selects the register page
21
RxWait
selects the time interval after transmission, before receiver starts
22
ChannelRedundancy
selects the kind and mode of checking the data integrity on the RF-
channel
23
CRCPresetLSB
LSB of the pre-set value for the CRC register
24
CRCPresetMSB
MSB of the pre-set value for the CRC register
25
TimeSlotPeriod selects the time between automatically mitted Frames see chapter 9.2.5
26
SIGOUTSelect
selects internal signal applied to pin SIGOUT
includes the MSB of value TimeSlotPeriod see register 0x25
27
PreSet27
these values shall not be changed
28
Page
Selects the register page
29
FIFOLevel
defines level for FIFO over– and underflow warning
2A
TimerClock
selects the divider for the timer clock
2B
TimerControl
selects start and stop conditions for the timer
2C
TimerReload
defines the pre-set value for the timer
2D
IrqPinConfig
configures the output stage of pin IRq
2E
PreSet2E
these values shall not be changed
2F
PreSet2F
these values shall not be changed
30
Page
selects the register page
31
RFU
reserved for future use
32
RFU
reserved for future use
33
RFU
reserved for future use
34
RFU
reserved for future use
35
RFU
reserved for future use
36
RFU
reserved for future use
37
RFU
reserved for future use
38
Page
selects the register page
39
RFU
reserved for future use
3A
TestAnaSelect
selects analog test mode
3B
PreSet3B
these values shall not be changed
3C
PreSet3C
these values shall not be changed
3D
TestDigiSelect
selects digital test mode
3E
RFU
reserved for future use
3F
RFU
reserved for future use
Table 5-1: SL RC400 Register Overview
17
Preliminary