3 0 Functional Description (Continued)
3 2 7 Exception Acknowledge Sequences
Detailed Flow
For purposes of the following detailed discussion of excep-
tion acknowledge sequences a single sequence called
‘‘service’’ is defined in Figure 3-12
Upon detecting any interrupt request or trap condition the
CPU first performs a sequence dependent upon the type of
exception This sequence will include saving a copy of the
Processor Status Register and establishing a vector and a
return address The CPU then performs the service se-
quence
3 2 7 1 Maskable Non-Maskable Interrupt Sequence
This sequence is performed by the CPU when the NMI pin
receives a falling edge or the INT pin becomes active with
the PSR I bit set The interrupt sequence begins either at
the next instruction boundary or in the case of the String
instructions or Graphics instructions which have interior
loops (BBOR BBXOR BBAND BBFOR EXTBLT MOVMP
SBITPS TBITS) at the next interruptible point during its ex-
ecution The graphics instructions are interruptible
1 If a String instruction was interrupted and not yet com-
pleted
a Clear the Processor Status Register P bit
b Set ‘‘Return Address’’ to the address of the first byte
of the interrupted instruction
Otherwise set ‘‘Return Address’’ to the address of the
next instruction
2 Copy the Processor Status Register (PSR) into a tempo-
rary register then clear PSR bits S U T P and I
3 If the interrupt is Non-Maskable
a Read a byte from address FFFF0016 applying Status
Code 0100 (Interrupt Acknowledge Master Section
3 4 1) Discard the byte read
b Set ‘‘Vector’’ to 1
c Go to Step 8
4 If the interrupt is Non-Vectored
a Read a byte from address FFFE0016 applying Status
Code 0100 Discard the byte read
b Set ‘‘Vector’’ to 0
c Go to Step 8
5 Here the interrupt is Vectored Read ‘‘Byte’’ from ad-
dress FFFE0016 applying Status Code 0100
6 If ‘‘Byte’’ t 0 then set ‘‘Vector’’ to ‘‘Byte’’ and go to
Step 8
7 If ‘‘Byte’’ is in the range b16 through b1 then the inter-
rupt source is Cascaded (More negative values are re-
served for future use ) Perform the following
a Read the 32-bit Cascade Address from memory The
address is calculated as INTBASE a 4 Byte
b Read ‘‘Vector’’ applying the Cascade Address just
read and Status Code 0101
8 Perform Service (Vector Return Address) Figure 3-12
3 2 7 2 SLAVE ILL SVC DVZ FLG BPT UND
Trap Sequence
1 Restore the currently selected Stack Pointer and the
Processor Status Register to their original values at the
start of the trapped instruction
2 Set ‘‘Vector’’ to the value corresponding to the trap type
SLAVE Vector e 3
ILL
Vector e 4
SVC Vector e 5
DVZ Vector e 6
FLG Vector e 7
BPT Vector e 8
UND Vector e 10
3 If Trap (UND)
a Clear the Processor Status Register P Bit
4 Copy the Processor Status Register (PSR) into a tempo-
rary register then clear PSR bits T U S and P
5 Set ‘‘Return Address’’ to the address of the first byte of
the trapped instruction
6 Perform Service (Vector Return Address) Figure 3-12
3 2 7 3 Trace Trap Sequence
1 In the Processor Status Register (PSR) clear the P bit
2 Copy the PSR into a temporary register then clear PSR
bits S U and T
3 Set ‘‘Vector’’ to 9
4 Set ‘‘Return Address’’ to the address of the next instruc-
tion
5 Perform Service (Vector Return Address) Figure 3-12
Service (Vector Return Address)
1 Push the PSR copy onto the Interrupt Stack as a
16-bit value
2 Read 32-bit Interrupt Dispatch Table (IDT) entry
at address ‘‘INTBASE a vector c 4’’
3 If Direct-Exception mode is selected then go to
Step 10
4 Move the LS word of the IDT entry (Module
Field) into the temporary MOD register
5 Read the Program Base pointer from memory
address ‘‘MOD a 8’’ and add to it the M S word
of the IDT entry (Offset Field) placing the result
in the Program Counter
6 Read the new Static Base pointer from the
memory address contained in MOD placing it
into the SB Register
7 Push MOD Register into the Interrupt Stack as a
16-bit value
8 Copy temporary MOD Register into MOD Regis-
ter
9 Go to Step 11
10 Place IDT entry in the Program Counter
11 Push the Return Address onto the Interrupt
Stack as a 32-bit quantity
12 Flush queue Non-sequentially fetch first in-
struction of Exception Service Routine
FIGURE 3-12 Service Sequence
Invoked during All Interrupt Trap Sequences
39