English
Language : 

71M6541D Datasheet, PDF (120/166 Pages) Maxim Integrated Products – 0.1% Accuracy Over 2000:1 Current Range Energy Meter ICs
71M6541D/F/G and 71M6542F/G Data Sheet
Name
PLL_FAST
PLS_MAXWIDTH[7:0]
PLS_INTERVAL[7:0]
PLS_INV
PORT_E
PRE_E
PREBOOT
RCMD[4:0]
RESET
RFLY_DIS
Location
2200[4]
210A[7:0]
210B[7:0]
210C[0]
270C[5]
2704[5]
SFRB2[7]
SFR FC[4:0]
2200[3]
210C[3]
Rst Wk Dir Description
Controls the speed of the PLL and MCK.
0 0 R/W 1 = 19.66 MHz (XTAL * 600)
0 = 6.29 MHz (XTAL * 192)
PLS_MAXWIDTH[7:0] determines the maximum width of the pulse (low-going
pulse if PLS_INV=0 or high-going pulse if PLS_INV=1). The maximum pulse
FF FF
R/W
width is (2*PLS_MAXWIDTH[7:0] + 1)*TI. Where TI is PLS_INTERVAL[7:0] in
units of CK_FIR clock cycles. If PLS_INTERVAL[7:0] = 0 or
PLS_MAXWIDTH[7:0] = 255, no pulse width checking is performed and the
output pulses have 50% duty cycle. See 2.3.6.2 VPULSE and WPULSE.
PLS_INTERVAL[7:0] determines the interval time between pulses. The time
between output pulses is PLS_INTERVAL[7:0]*4 in units of CK_FIR clock
cycles. If PLS_INTERVAL[7:0] = 0, the FIFO is not used and pulses are output
as soon as the CE issues them. PLS_INTERVAL[7:0] is calculated as follows:
PLS_INTERVAL[7:0] = Floor ( Mux frame duration in CK_FIR cycles / CE pulse
updates per Mux frame / 4 )
0 0 R/W
For example, since the 71M654x CE code is written to generate 6 pulses in one
integration interval, when the FIFO is enabled (i.e., PLS_INTERVAL[7:0] ≠ 0)
and that the frame duration is 1950 CK_FIR clock cycles, PLS_INTERVAL[7:0]
should be written with Floor(1950 / 6 / 4) = 81 so that the five pulses are
evenly spaced in time over the integration interval and the last pulse is issued
just prior to the end of the interval. See 2.3.6.2 VPULSE and WPULSE.
Inverts the polarity of WPULSE, VARPULSE, XPULSE and YPULSE.
0 0 R/W Normally, these pulses are active low. When inverted, they become active
high.
Enables outputs from the pins SEGDIO0-SEGDIO15. PORT_E = 0 after reset
0 0 R/W and power-up blocks the momentary output pulse that would occur on
SEGDIO0 to SEGDIO15.
0 0 R/W Enables the 8x pre-amplifier.
– – R Indicates that pre-boot sequence is active.
When the MPU writes a non-zero value to RCMD[4:0], the IC issues a
0 0 R/W command to the appropriate remote sensor. When the command is complete,
the IC clears RCMD[4:0].
0 0 W When set, writes a one to WF_RSTBIT and then causes a reset.
Controls how the IC drives the power pulse for the 71M6x01. When set, the
0 0 R/W power pulse is driven high and low. When cleared, it is driven high followed
by an open circuit fly-back interval.