X3100, X3101
OPERATING CHARACTERISTICS X3100
(Over the recommended operating conditions unless otherwise specified)
Description
5V regulated voltage
5VDC voltage regulator current
limit
VCC supply current (1)
VCC supply current (2)
VCC supply current (3)
VCC supply current (4)
VCC supply current (5)
Cell over-charge protection mode
voltage threshold
(Default in Boldface)
Sym
VRGO
ILMT(3)
Condition
On power-up or at wake-up
After self-tuning
(@10mA VRGO current; 25oC)
After self-tuning
(@10mA VRGO current; 0 - 50oC)(5)
After self-tuning
(@50mA VRGO current)(5)
RLMT = 10Ω
Icc1
Icc2
Icc3
Icc4
Icc5
VOV(4)
Normal operation
during nonvolatile EEPROM write
During EEPROM read
SCK=3.3MHz
Sleep mode
Monitor mode
AN2, AN1, AN0 not equal to 0.
VOV = 4.20V (VOV1, VOV0 = 0,0)
0oC to 50oC
VOV = 4.25V (VOV1, VOV0 = 0,1)
0oC to 50oC
Min
4.5
4.98
4.95
4.90
4.10
4.15
4.15
4.20
VOV = 4.30V (VOV1, VOV0 = 1,0)
0oC to 50oC
4.2
4.25
Cell over-charge protection mode
release voltage threshold
Cell over-charge detection time
Cell over-discharge protection
mode (SLEEP) threshold.
(Default in Boldface)
Cell over-discharge protection
mode release threshold
Cell over-discharge detection time
Cell over-discharge release time
VOV = 4.35V (VOV1, VOV0 = 1,1)
0oC to 50oC
VOVR
TOV
VUV(4)
VUVR
COV = 0.1uF
VUV = 1.95V (VUV1, VUV0 = 0,0)
VUV = 2.05V (VUV1, VUV0 = 0,1)
VUV = 2.15V (VUV1, VUV0 = 1,0)
VUV = 2.25V (VUV1, VUV0 = 1,1)
TUV
TUVR
CUV = 0.1µF
CUV = 200pF
CUV = 0.1µF
CUV = 200pF
4.25
4.30
1.85
1.95
2.05
2.15
Typ(2)
4.99
Max
5.5
5.00
Unit
V
5.02
5.00 V
250
mA
85
250 µA
1.3
2.5 mA
0.9
1.2 mA
1
µA
365
600 µA
VOV -
0.20
1
VUV +
0.7
1
2
7
100
4.275 V
4.25
4.325 V
4.30
4.375 V
4.35
4.425 V
4.40
V
s
2.05 V
2.15 V
2.25 V
2.35 V
V
s
ms
ms
µs
31
FN8110.1
January 3, 2008