English
Language : 

X3100-01 Datasheet, PDF (30/41 Pages) Intersil Corporation – Cell Balancing Control
X3100, X3101
ABSOLUTE MAXIMUM RATINGS
Symbol
VCC
VCELL
VTERM1
VTERM2
VTERM3
Parameter
Storage temperature
Operating temperature
DC output current
Lead temperature (soldering 10 seconds)
Power supply voltage
Cell voltage
Terminal voltage (Pins: SCK, SI, SO, CS, AS0, AS1, AS2, VCS1,
VCS2, OVT, UVT, OCT, AO)
Terminal voltage (VCELL1)
Terminal voltage (all other pins)
Min.
-55
-40
VSS-0.5
-0.5
VSS-0.5
Max.
125
85
5
300
VSS+27.0
6.75
VRGO + 0.5
VSS-0.5
VSS-0.5
VCC + 1.0
VCC + 0.5
Unit
°C
°C
mA
°C
V
V
V
V
V
Stresses above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is
a stress rating only; the functional operation of the device (at these or any other conditions above those indicated in
the operational sections of this specification) is not implied. Exposure to absolute maximum rating conditions for
extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
Temperature
Commercial
Min.
-20°C
Max.
+70°C
Supply Voltage
X3100/X3101
Limits
6V to 24V
D.C. OPERATING CHARACTERISTICS
(Over the recommended operating conditions, unless otherwise specified.)
Limits
Symbol
Parameter
Min.
Max.
ILI
Input leakage current (SCK, SI, CS,
±10
ASO, AS1, AS2)
ILO
VIL(1)
VIH(1)
VOL1
VOH1
VOL2
VOH2
Output leakage current (SO)
Input LOW voltage
(SCK, SI, CS, AS0, AS1, AS2)
Input HIGH voltage
(SCK, SI, CS, AS0, AS1, AS2)
Output LOW voltage (SO)
Output HIGH voltage (SO)
Output LOW voltage
(UVP/OCP, OVP/LMON, CB1-CB4)
Output HIGH voltage
(UVP/OCP, OVP/LMON, CB1-CB4)
- 0.3
±10
VRGO x 0.3
VRGO x 0.7 VRGO + 0.3
0.4
VRGO - 0.8
0.4
VCC-0.4
VOL3 Output LOW voltage (RGC)
0.4
VOH3 Output HIGH voltage (RGC)
VCC-4.0
Note: (1) VIL min. and VIH max. are for reference only and are not 100% tested.
Units
µA
µA
V
V
V
V
V
V
V
V
Test Conditions
IOL = 1.0mA
IOH = -0.4mA
IOL = 100uA
IOH = -20uA
IOL = 2mA, RGP = VCC,
RGO = 5V
IOH = -20µA, RGP = VCC - 4V,
RGO = 5V
30
FN8110.1
January 3, 2008