English
Language : 

K10P81M100SF2 Datasheet, PDF (8/60 Pages) Freescale Semiconductor, Inc – K10 Sub-Family Data Sheet
Terminology and guidelines
3.6 Relationship between ratings and operating requirements
Operating or handling rating (min.)
Operating requirement (min.)
Operating requirement (max.)
Operating or handling rating (max.)
Fatal
range
- Probable permanent failure
Limited
operating
range
- No permanent failure
- Possible decreased life
- Possible incorrect operation
Normal
operating
range
- No permanent failure
- Correct operation
Limited
operating
range
- No permanent failure
- Possible decreased life
- Possible incorrect operation
Fatal
range
- Probable permanent failure
Handling range
- No permanent failure
–∞
∞
ry 3.7 Guidelines for ratings and operating requirements
a Follow these guidelines for ratings and operating requirements:
in • Never exceed any of the chip’s ratings.
• During normal operation, don’t exceed any of the chip’s operating requirements.
• If you must exceed an operating requirement at times other than during normal
operation (for example, during power sequencing), limit the duration as much as
lim possible.
3.8 Definition: Typical value
e A typical value is a specified value for a technical characteristic that:
r • Lies within the range of values specified by the operating behavior
• Given the typical manufacturing process, is representative of that characteristic
P during operation when you meet the typical-value conditions or other specified
conditions
Typical values are provided as design guidelines and are neither tested nor guaranteed.
3.8.1 Example 1
This is an example of an operating behavior that includes a typical value:
Symbol
IWP
Description
Min.
Digital I/O weak 10
pullup/pulldown
current
Typ.
70
Max.
130
Unit
µA
K10 Sub-Family Data Sheet Data Sheet, Rev. 1, 11/2010.
8
Preliminary
Freescale Semiconductor, Inc.