English
Language : 

MC9S08GB60A Datasheet, PDF (163/302 Pages) Freescale Semiconductor, Inc – HCS08 Microcontrollers
Timer/PWM (TPM)
10.6 TPM Interrupts
The TPM generates an optional interrupt for the main counter overflow and an interrupt for each channel.
The meaning of channel interrupts depends on the mode of operation for each channel. If the channel is
configured for input capture, the interrupt flag is set each time the selected input capture edge is
recognized. If the channel is configured for output compare or PWM modes, the interrupt flag is set each
time the main timer counter matches the value in the 16-bit channel value register. See the Resets,
Interrupts, and System Configuration chapter for absolute interrupt vector addresses, priority, and local
interrupt mask control bits.
For each interrupt source in the TPM, a flag bit is set on recognition of the interrupt condition such as timer
overflow, channel input capture, or output compare events. This flag may be read (polled) by software to
verify that the action has occurred, or an associated enable bit (TOIE or CHnIE) can be set to enable
hardware interrupt generation. While the interrupt enable bit is set, a static interrupt will be generated
whenever the associated interrupt flag equals 1. It is the responsibility of user software to perform a
sequence of steps to clear the interrupt flag before returning from the interrupt service routine.
10.6.1 Clearing Timer Interrupt Flags
TPM interrupt flags are cleared by a 2-step process that includes a read of the flag bit while it is set (1)
followed by a write of 0 to the bit. If a new event is detected between these two steps, the sequence is reset
and the interrupt flag remains set after the second step to avoid the possibility of missing the new event.
10.6.2 Timer Overflow Interrupt Description
The conditions that cause TOF to become set depend on the counting mode (up or up/down). In
up-counting mode, the 16-bit timer counter counts from $0000 through $FFFF and overflows to $0000 on
the next counting clock. TOF becomes set at the transition from $FFFF to $0000. When a modulus limit
is set, TOF becomes set at the transition from the value set in the modulus register to $0000. When the
counter is operating in up-/down-counting mode, the TOF flag gets set as the counter changes direction at
the transition from the value set in the modulus register and the next lower count value. This corresponds
to the end of a PWM period. (The $0000 count value corresponds to the center of a period.)
10.6.3 Channel Event Interrupt Description
The meaning of channel interrupts depends on the current mode of the channel (input capture, output
compare, edge-aligned PWM, or center-aligned PWM).
When a channel is configured as an input capture channel, the ELSnB:ELSnA control bits select rising
edges, falling edges, any edge, or no edge (off) as the edge that triggers an input capture event. When the
selected edge is detected, the interrupt flag is set. The flag is cleared by the 2-step sequence described in
Section 10.6.1, “Clearing Timer Interrupt Flags.”
When a channel is configured as an output compare channel, the interrupt flag is set each time the main
timer counter matches the 16-bit value in the channel value register. The flag is cleared by the 2-step
sequence described in Section 10.6.1, “Clearing Timer Interrupt Flags.”
MC9S08GB60A Data Sheet, Rev. 2
Freescale Semiconductor
163