MC908AP16CFAE Datasheet, PDF (163/324 Pages) Freescale Semiconductor, Inc – Table of Contents
Functional Description
Start bit verification is not successful if any two of the three verification samples are logic 1s. If start bit
verification is not successful, the RT clock is reset and a new search for a start bit begins.
To determine the value of a data bit and to detect noise, recovery logic takes samples at RT8, RT9, and
RT10. Table 11-3 summarizes the results of the data bit samples.
Table 11-3. Data Bit Recovery
RT8, RT9, and RT10
Samples
000
001
010
011
100
101
110
111
Data Bit
Determination
0
0
0
1
0
1
1
1
Noise Flag
0
1
1
1
1
1
1
0
NOTE
The RT8, RT9, and RT10 samples do not affect start bit verification. If any
or all of the RT8, RT9, and RT10 start bit samples are logic 1s following a
successful start bit verification, the noise flag (NF) is set and the receiver
assumes that the bit is a start bit.
To verify a stop bit and to detect noise, recovery logic takes samples at RT8, RT9, and RT10. Table 11-4
summarizes the results of the stop bit samples.
Table 11-4. Stop Bit Recovery
RT8, RT9, and RT10
Samples
000
001
010
011
100
101
110
111
Framing
Error Flag
1
1
1
0
1
0
0
0
Noise Flag
0
1
1
1
1
1
1
0
MC68HC908AP Family Data Sheet, Rev. 4
Freescale Semiconductor
163