M14D1G1664A (2S)
Automotive Grade
Parameter
Symbol
Test Condition
Version
Unit
-1.8
-2.5
tCK = tCK (IDD);
Refresh command every tRFC (IDD) interval;
Auto Refresh Current IDD5 CKE is HIGH, CS is HIGH between valid commands; 115
110
mA
Other control and address bus inputs are SWITCHING;
Data bus inputs are SWITCHING
Self Refresh Mode;
Self Refresh Current
IDD6
CLK and CLK at 0V; CKE  0.2V;
Other control and address bus inputs are FLOATING;
8
mA
Data bus inputs are FLOATING
Operating Current
(Bank interleaving)
All bank interleaving Reads, IOUT = 0mA;
BL = 4, CL= CL (IDD), AL = tRCD (IDD) – 1 × tCK (IDD);
tCK = tCK (IDD), tRC = tRC (IDD),
IDD7 tRRD = tRRD (IDD), tRCD = 1 × tCK (IDD);
195
CKE is HIGH, CS is HIGH between valid commands;
185
mA
Address bus inputs are STABLE during Deslects;
Data pattern is the same as IDD4W;
Note:
1. IDD specifications are tested after the device is properly initialized.
2. Input slew rate is specified by AC Input Test Condition.
3. IDD parameters are specified with ODT disabled.
4. Data bus consists of DQ, DM, DQS and DQS , IDD values must be met with all combinations of EMRS bits 10 and 11.
5. Definitions for IDD:
LOW is defined as VIN  VIL (AC) (max.).
HIGH is defined as VIN VIH (AC) (min.).
STABLE is defined as inputs stable at a HIGH or LOW level.
FLOATING is defined as inputs at VREF = VDDQ/2
SWITCHING is defined as:
Address and control signal Inputs are changed between HIGH and LOW every other clock cycle (once per two clocks), and
DQ (not including mask or strobe) signal inputs are changed between HIGH and LOW every other data transfer (once per
clock).
6. The following IDD values must be derated (IDD limits increase), when TC ≧ +85 ℃. IDD2P must derated by 20%; IDD3P
(slow) must derated by 30% and IDD6 must be derated by 80%. (IDD6 will increase by this amount if TC ≧ +85 ℃ and
double refresh option is still enabled. )
7. AC Timing for IDD test conditions
For purposes of IDD testing, the following parameters are to be utilized.
Parameter
-1.8
-2.5
Unit
DDR2-1066 (6-6-6)
DDR2-800 (5-5-5)
CL (IDD)
tRCD (IDD)
tRC (IDD)
tRRD (IDD)
tFAW (IDD)
6
11.25
56.25
10
45
5
tCK
12.5
ns
57.5
ns
10
ns
45
ns
tCK (IDD)
1.875
2.5
ns
tRAS (IDD) min.
45
45
ns
tRAS (IDD) max.
70000
ns
tRP (IDD)
11.25
12.5
ns
tRFC (IDD)
127.5
127.5
ns
Elite Semiconductor Memory Technology Inc.
Publication Date : Jul. 2014
Revision : 0.1
7/65