2. Product Specifications
2.1 Absolute Maximum Ratings
Table 2.1 Absolute Maximum Ratings
Parameter
Min.
VCC to GND
−0.3
Digital Input Voltage to GND
−0.3
Digital Output Voltage to GND
−0.3
Storage Temperature Range
−40
Acceleration / Shock (Half-sine 0.5msec)
-
Typ.
-
-
-
-
-
Max.
6.0
5.3
VCC +0.3
85
500
Unit
V
V
V
°C
G
Precautions about ESD
Electrostatic discharge (ESD) may damage the product.
When you store or handle the product, take appropriate preventive measures against electrostatic
discharge (ESD).
Damages caused by electrostatic discharge (ESD) range from tiny performance degradation or partial
malfunction to complete breakdown.
This is a high-precision product. Even tiny performance degradation may cause the product not to
conform to the specifications.
2.2 Recommended Operating Condition
Table 2.2 Recommended Operating Conditions
Parameter
condition
Min.
Typ.
Max.
Unit
VCC to GND
3.15
3.3
3.45
V
Digital Input Voltage to GND
GND
-
VCC
V
Digital Output Voltage to GND
−0.3
-
VCC +0.3
V
Calibration temperature range Performance parameters are
−20
-
70
°C
applicable
Operating Temperature Range
−40
-
85
°C
2
Seiko Epson Corporation
M-G362PDC1 Data Sheet
Rev.20131217