Please note that the transient response of the digital filter is a maximum of 63 samples from the
sampling start time and varies depending on the output data rate and the filter tap setting. Refer to Table
5.3 which describes the transient response in terms of number of samples for valid combinations of
output data rate and filter tap setting.
Table 5.3 Transient Response in Number of Samples Based on Output Data Rate vs Filter Tap
TAP2
TAP4
TAP8
TAP16 TAP32 TAP64 TAP128
2000sps 0
1
3
7
15
31
63
1000sps
500sps
0
1
3
7
15
31
0
1
3
7
15
250sps
0
1
3
7
125sps
62.5sps
0
1
3
0
1
31.25sps
0
24
Seiko Epson Corporation
M-G362PDC1 Data Sheet
Rev.20131217