Figure 14. Reset Logic
DATA BUS
MCU Control and Status
Register (MCUCSR)
BODEN
BODLEVEL
Brown-Out
Reset Circuit
Pull-up Resistor
SPIKE
FILTER
Watchdog
Oscillator
Clock
CK
Generator
CKSEL[3:0]
SUT[1:0]
Delay Counters
TIMEOUT
Table 15. Reset Characteristics
Symbol Parameter
Condition
Min Typ Max Units
VPOT
Power-on Reset Threshold
Voltage (rising)(1)
Power-on Reset Threshold
Voltage (falling)
1.4 2.3
V
1.3 2.3
V
VRST
tRST
RESET Pin Threshold Voltage
Minimum pulse width on
RESET Pin
0.2
0.9
VCC
1.5 µs
VBOT
Brown-out Reset Threshold
Voltage(2)
BODLEVEL = 1 2.4 2.6 2.9
V
BODLEVEL = 0 3.7 4.0 4.5
Minimum low voltage period for BODLEVEL = 1
2
µs
tBOD Brown-out Detection
BODLEVEL = 0
2
µs
VHYST Brown-out Detector hysteresis
130
mV
Notes:
1. The Power-on Reset will not work unless the supply voltage has been below VPOT (falling).
2. VBOT may be below nominal minimum operating voltage for some devices. For devices where
this is the case, the device is tested down to VCC = VBOT during the production test. This guar-
antees that a Brown-out Reset will occur before VCC drops to a voltage where correct
operation of the microcontroller is no longer guaranteed. The test is performed using
BODLEVEL = 1 for ATmega8L and BODLEVEL = 0 for ATmega8. BODLEVEL = 1 is not appli-
cable for ATmega8.
38 ATmega8(L)
2486T–AVR–05/08