AK4649 Datasheet, PDF (23/96 Pages) Asahi Kasei Microsystems – 24bit Stereo CODEC with MIC/SPK-AMP | |||
|
◁ |
[AK4649]
OPERATION OVERVIEW
â System Clock
There are the following five clock modes to interface with external devices (Table 1, Table 2).
Mode
PMPLL bit
M/S bit
PLL3-0 bits
Figure
PLL Master Mode (Note 33)
1
1
Table 4
Figure 14
PLL Slave Mode 1
(PLL Reference Clock: MCKI pin)
1
0
Table 4
Figure 15
PLL Slave Mode 2
(PLL Reference Clock: LRCK or BICK
1
pin)
0
Table 4
Figure 16
Figure 17
EXT Slave Mode
0
0
x
Figure 18
EXT Master Mode
0
1
x
Figure 19
Note 33. If M/S bit = â1â, PMPLL bit = â0â and MCKO bit = â1â during the setting of PLL Master Mode, the invalid
clocks are output from the MCKO pin.
Table 1. Clock Mode Setting (x: Donât care)
Mode
MCKO bit MCKO pin MCKI pin BICK pin LRCK pin
PLL Master Mode
0
1
L
Selected by
PS1-0 bits
Selected by
PLL3-0 bits
Output
(Selected by
BCKO bit)
Output
(1fs)
PLL Slave Mode
(PLL Reference Clock: MCKI pin)
0
1
L
Selected by
PS1-0 bits
Selected by
PLL3-0 bits
Input
(Selected by
BCKO bit)
Input
(1fs)
PLL Slave Mode
(PLL Reference Clock: LRCK or BICK
0
pin)
L
GND
Input
(Selected by
BCKO bit)
Input
(1fs)
EXT Slave Mode
0
L
Selected by
PLL3-0 bits
Input
(⥠32fs)
Input
(1fs)
EXT Master Mode
0
L
Selected by
PLL3-0 bits
Output
(Selected by
BCKO bit)
Output
(1fs)
Note 34. When PMVCM bit = M/S bit = â1â and MCKI is input, LRCK and BICK are output, even if PMDAC bit =
PMADL bit = PMADR bit = â0â.
Table 2. Clock pins state in Clock Mode
â Master Mode/Slave Mode
The M/S bit selects either master or slave mode. M/S bit = â1â selects master mode and â0â selects slave mode. When the
AK4649 is power-down mode (PDN pin = âLâ) and exits reset state, the AK4649 is in slave mode. After exiting reset
state, the AK4649 goes to master mode by changing M/S bit = â1â.
When the AK4649 is in master mode, the LRCK and BICK pins are a floating state until M/S bit becomes â1â. The LRCK
and BICK pins of the AK4649 must be pulled-down or pulled-up by the resistor (about 100kΩ) externally to avoid the
floating state.
M/S bit
Mode
0
Slave Mode
1
Master Mode
Table 3. Select Master/Slave Mode
(default)
MS1023-E-01
- 23 -
2010/08
|
▷ |