LU3X54FTL Datasheet, PDF (40/52 Pages) Agere Systems – QUAD-FET for 10Base-T/100Base-TX/FX
LU3X54FTL
QUAD-FET for 10Base-T/100Base-TX/FX
Data Sheet
July 2000
MII Station Management (continued)
Unmanaged Operations
The LU3X54FTL allows the user to set some of the station management functions during powerup or reset by
strapping outputs high or low through weak resistors (50 kΩ). Table 23 shows the functions and their associated
output pin. For detailed information on the function of these output pins, refer to the section on management regis-
ters described earlier in this data sheet. Also, information on how these output pins should be strapped is dis-
cussed in the Pin Descriptions section (Table 3 through Table 7).
Table 23. Output Pins
Function (Register/Bit)
PHYADD[2:0]
NO_LP
SPEED
CARIN_EN
ENC_DEC_BYPASS
SCRAM_DESC_BYPASS
REF_SEL
CLK20_SEL
FULL _DUP
SERIAL_SEL
CRS_SEL
BUSED_MII_MODE
SMART_MODE_SELECT
ISOLATE_MODE
FX_MODE_EN
RESERVED
Pin
LINKLED[D:B]
LINKLED[A]
SPEEDLED[D]
TXLED[D]
TXLED[C]
TXLED[B]
TXLED[A]
H_DUPLED[A]
H_DUPLED[D]
H_DUPLED[C]
H_DUPLED[B]
SPEEDLED[B]
SPEEDLED[C]
SPEEDLED[A]
RXLED[D:A]
COLED[B:A]
Internal Pull-Up/Pull-Down
None
50 kΩ down
100 kΩ up
50 kΩ down
50 kΩ down
50 kΩ down
50 kΩ down
50 kΩ down
50 kΩ down
50 kΩ down
50 kΩ down
50 kΩ down
50 kΩ down
50 kΩ down
50 kΩ down
50 kΩ down
Mode Select
Table 24. LU3X54FTL Modes
MODE[4:0]
00000
00001—11111
Description
Normal operation
Reserved
40