85
11.3 AC Characteristics
The numbers in Table 74 correspond to the numbered signal segments in
Figure 22.
Table 74 AC Characteristics
No. Symbol
Parameter
Min Max Unit
1 TpC
Input Clock Period
166 1000 ns
2 TRC, TFC
Clock Input Rise And Fall Time
25
ns
3 TWC
Input Clock Width
35
ns
4 TWHsyncINL
Hsync Input Low Width
70
ns
5 TWHsyncINH
Hsync Input High Width
3TpC
6 TpHsyncIN
Hsync Input Period
8TpC
7 TRHsyncIN, TFHsyncIN Hsync Input Rise Fall Time
100 ns
8 TWIL
Interrupt Request Input Low
70
ns
9 TWIH
Interrupt Request Input High 3TpC
10 TDPOR
Power-On Reset Delay
25
100 ms
11 TDLVIRES
Low Voltage Detect To Internal 200
ns
Reset Condition
12 TWRES
13 TDHSOl
14 TDHSOH
Reset Minimum Width
Hsync Start To OSDX2 Stop
Hsync Start To OSDX2 Start
5TpC
2TpV
3TpV
1TpV
PS001301-0800