English
Language : 

W972GG6JB-18-TR Datasheet, PDF (14/87 Pages) Winbond – 16M 8 BANKS 16 BIT DDR2 SDRAM
W972GG6JB
8.2.2.4 Extend Mode Register Set Command (3), EMR (3)
( CS = "L", RAS = "L", CAS = "L", WE = "L", BA0 = "H", BA1 = "H", BA2 = "L", A0 to A13 =
Register data)
No function is defined in extended mode register (3). The default value of the EMR (3) is not defined,
therefore the EMR (3) must be programmed during initialization for proper operation.
BA2 BA1 BA0 A13 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1 A0
Address Field
0*1 1
1
0*1
Extended Mode Register (3)
Note:
1. All bits in EMR(3) except BA0 and BA1 are reserved for future use and must be set to “0” when programming the EMR(3).
Figure 5 – EMR (3)
- 14 -