14.9.3
Control Register: CODEC_CTRL
The functional description and read/write status of each bit are illustrated in this section. The read or write status of each bit is indicated
by the symbol R or W described in Table 14-1.
SYMBOL
TYPE
MEANING
R/W
Read/Write Data may be read or written by micro-processor.
Table 14-1: Read/Write status description in control register
Address
0x1509
Access Mode Value At Reset Nominal Value
R/W
0xC0
Bit 7
CODEC
DigDis
Bit 6
Bit 5
CODECAPd Reserved
Bit 4
Reserved
Bit 3
Analog
Loopback
Bit 2
Reserved
Bit 1
Reserved
Bit 0
Reserved
CODECDigDis [Bit7]:
CODECAPd [Bit6]:
Analog Loopback [Bit 3]:
=1, Disable the CODEC digital part,
=0, Enable the CODEC digital part.
=1, To disabled the CODEC analog part to save power. Especially when using the PDM
mode sounder signal, only the CODEC digital filter is necessary.
=0, CODEC analog part enabled.
=1, Setting this bit causes an analog loopback from the receive path to the transmit path.
Internally the RO output in the receive path is routed to the transmit gain control in the
transmit path; the op-amp TG is bypassed. This feature is useful for self-testing to neglect
the external connecting circuit, shown in Figure 14-7.
.
Figure 14-7 The signal flow of Analog Lookback