Language : 

DS100DF410 Datasheet, PDF (5/43 Pages) Texas Instruments – Low Power 10GbE Quad Channel Retimer
DS100DF410
www.ti.com
Pin Name
SDA
SDC
ADDR_0
ADDR_1
ADDR_2
ADDR_3
POWER
VDD
GND
DAP
Pin #
18
17
45
40
21
16
SNLS399A – JANUARY 2012 – REVISED FEBRUARY 2013
Pin Descriptions (continued)
I/O, Type(1)
Description
I/O, 3.3V Data Input / Open Drain Output
LVCMOS, Open External 2KΩ to 5KΩ pull-up resistor is required.
Drain
Pin is 3.3 V LVCMOS tolerant.
I/O, 3.3V Clock Input / Open Drain Clock Output
LVCMOS, Open External 2KΩ to 5KΩ pull-up resistor is required.
Drain
Pin is 3.3 V LVCMOS tolerant.
I, 2.5V
LVCMOS
Input is 2.5 V, the ADDR_[3:0] pins set the SMBus address for the retimer.
These pins are strap inputs. Their state is read on power-up to set the SMBus
address in SMBus control mode.
High = 1KΩ to VDD, Low = 1KΩ to GND
Note that these pins are shared with the lock indicator functions. See Table 2
3, 6, 7,
10, 15, 46
22, 27,
30, 31,
34, 39
PAD
Power
Power
VDD = 2.5 V ± 5%
Ground reference.
Power
Ground reference. The exposed pad at the center of the package must be
connected to ground plane of the board with at least 4 vias to lower the ground
impedance and improve the thermal performance of the package.
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
Absolute Maximum Ratings (1)
Supply Voltage (VDD)
2.5 I/O Voltage
(LVCMOS and Analog)
3.3 LVCMOS I/O Voltage
(SDA, SDC, INT)
Signal Input Voltage (RXPn, RXNn)
Signal Output Voltage (TXPn, TXNn)
Junction Temperature
Storage Temperature
ESD Rating
HBM, STD - JESD22-A114F
MM, STD - JESD22-A115-A
CDM, STD - JESD22-C101-D
Thermal Resistance
θJA, No Airflow,
4 layer JEDEC, 9 thermal vias
For soldering specifications: see http://www.ti.com/lit/an/snoa549c/snoa549c.pdf
-0.5V to +2.75V
-0.5V to +2.75V
-0.5V to +4.0V
-0.5V to +2.75V
-0.5V to +2.75V
+150°C
-65°C to +150°C
≥6 kV
≥250 V
≥1250 V
26.1 °C/W
(1) “Absolute Maximum Ratings” indicate limits beyond which damage to the device may occur, including inoperability and degradation of
device reliability and/or performance. Functional operation of the device and/or non-degradation at the Absolute Maximum Ratings or
other conditions beyond those indicated in the Recommended Operating Conditions is not implied.
Recommended Operating Conditions(1)
Supply Voltage (VDD to GND)
Ambient Temperature
Min
2.375
-40
Typ
Max
Units
2.5
2.625
V
25
+85
°C
(1) The Recommended Operating Conditions indicate conditions at which the device is functional and the device should not be operated
outside these conditions.
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: DS100DF410
Submit Documentation Feedback
5