English
Language : 

SI5364 Datasheet, PDF (23/40 Pages) Silicon Laboratories – SONET/SDH PRECISION PORT CARD CLOCK IC
2.13. Design and Layout Guidelines
Precision clock circuits are susceptible to board noise
and EMI. To take precautions against unacceptable
levels of board noise and EMI affecting performance of
the Si5364, consider the following:
Use an isolated, local plane to connect the VDD25
pins. Avoid running signal traces over or below this
plane without a ground plane in between.
Route all I/O traces between ground planes as much
as possible
Maintain an input clock amplitude in the 200 mVPP to
500 mVPP differential range.
Excessive high-frequency harmonics of the input
clock should be minimized. The use of filters on the
input clock signal can be used to remove high-
frequency harmonics.
Si5364
Rev. 2.2
23