Si5364
Table 4. AC Characteristics (PLL Performance Characteristics)
(VDD33 = 3.3 V ± 5%, TA = â20 to 85 °C)
Parameter
Symbol
Test Condition
Min Typ Max Unit
Wander/Jitter at 800 Hz Bandwidth
(BWSEL[1:0] = 10)
Jitter Tolerance (See Figure 8)
JTOL(PP)
f = 8 Hz
f = 80 Hz
1000 â
100 â
â ns
â ns
f = 800 Hz
10 â â ns
CLKOUT RMS Jitter Generation
FEC[1:0] = 00 (1/1 Scaling)
JGEN(RMS)
12 kHz to 20 MHz
50 kHz to 80 MHz
â 0.87 1.2 ps
â 0.26 0.35 ps
CLKOUT RMS Jitter Generation
FEC[1:0] = 01, 10 (255/238, 238/255 Scal-
ing)
CLKOUT Peak-Peak Jitter Generation
FEC[1:0] = 00 (1/1 Scaling)
JGEN(RMS)
JGEN(PP)
12 kHz to 20 MHz
50 kHz to 80 MHz
12 kHz to 20 MHz
50 kHz to 80 MHz
â 0.86 1.2 ps
â 0.26 0.35 ps
â 6.1 10.0 ps
â 2.1 5.0 ps
CLKOUT Peak-Peak Jitter Generation
FEC[1:0] = 01, 10 (255/238, 238/255 Scal-
ing)
Jitter Transfer Bandwidth (See Figure 9)
Wander/Jitter Transfer Peaking
Wander/Jitter at 1600 Hz Bandwidth
(BWSEL[1:0] = 01)
JGEN(PP)
FBW
JP
12 kHz to 20 MHz
50 kHz to 80 MHz
BW = 800 Hz
< 800 Hz
â 6.0 10.0 ps
â 2.0 5.0 ps
â 800 â Hz
â 0.0 0.05 dB
Jitter Tolerance (see Figure 8)
JTOL(PP)
f = 16 Hz
f = 160 Hz
1000 â â ns
100 â â ns
f = 1600 Hz
10 â â ns
CLKOUT RMS Jitter Generation
FEC[1:0] = 00
JGEN(RMS)
12 kHz to 20 MHz
50 kHz to 80 MHz
â 0.83 1.0 ps
â 0.26 0.35 ps
CLKOUT RMS Jitter Generation
FEC[1:0] = 01, 10
JGEN(RMS)
12 kHz to 20 MHz
50 kHz to 80 MHz
â 0.8 1.0 ps
â 0.26 0.35 ps
CLKOUT Peak-Peak Jitter Generation
FEC[1:0] = 00
JGEN(PP)
12 kHz to 20 MHz
50 kHz to 80 MHz
â 5.7 9.0 ps
â 2.0 5.0 ps
CLKOUT Peak-Peak Jitter Generation
FEC[1:0] = 01, 10
JGEN(PP)
12 kHz to 20 MHz
50 kHz to 80 MHz
â 5.4 9.0 ps
â 1.9 5.0 ps
Notes:
1. Higher PLL bandwidth settings provide smaller clock output wander with temperature gradient.
2. For reliable device operation, temperature gradients should be limited to 10 °C/min.
3. Telcordia GR-1244-CORE requirements specify maximum phase transient slope during clock rearrangement in terms
of nanoseconds per millisecond. The equivalent ps/µs unit is used here since the maximum phase transient magnitude
for the Si5364 (tPT_MTIE) never reaches one nanosecond.
10
Rev. 2.2
|
▷ |