 Usage Precautions
1. Feed-through current during detection and release
In the S-1011 Series, the feed-through current flows at the time of detection and release. For this reason, if the
input impedance is high, oscillation may occur due to voltage drop caused by the feed-through current.
When using the S-1011 Series in configurations like those shown in Figure 32 and Figure 33, it is recommended
that input impedance be set to 1 kΩ or less.
Determine the impedance through thorough evaluation including temperature characteristics.
RA
VBAT
VDD
VDD
OUT
VSS CP CN
VBAT
RA VDD
VDD
SENSE
OUT
VSS CP CN
Figure 32 VDD Detection Product
Figure 33 SENSE Detection Product