English
Language : 

S1011 Datasheet, PDF (22/43 Pages) Seiko Instruments Inc – BUILT-IN DELAY CIRCUIT (EXTERNAL DELAY TIME SETTING) VOLTAGE DETECTOR
HIGH-WITHSTAND VOLTAGE BUILT-IN DELAY CIRCUIT (EXTERNAL DELAY TIME SETTING) VOLTAGE DETECTOR
S-1011 Series
Rev.1.2_00
Also, the relation between the external setting hysteresis width (VHX) and the hysteresis width (VHYS) is calculated
by equation below. Error due to RSENSE also occurs to the relation in a similar way to the detection voltage.
( ) VHX = VHYS ×
1+
RA
RB
··· (4)
A
VDX
RA
−VDET
RB
VDD
SENSE
RSENSE
VSS
OUT
Figure 31 Detection Voltage External Setting Circuit
Caution 1. When externally setting the detection voltage, perform the operation with −VDET = 10.0 V product.
Contact our sales office for details.
2. If the current flowing through RB is set to 1 μA or less, the error may become larger.
3. If the parasitic resistance and parasitic inductance between VDX − point A and point A − VDD pin
are larger, oscillation may occur. Perform thorough evaluation using the actual application.
4. If RA and RB are large, the SENSE pin input impedance becomes higher and may cause a
malfunction due to noise. In this case, connect a capacitor between the SENSE pin and the VSS
pin.
22
Seiko Instruments Inc.