English
Language : 

S1011 Datasheet, PDF (12/43 Pages) Seiko Instruments Inc – BUILT-IN DELAY CIRCUIT (EXTERNAL DELAY TIME SETTING) VOLTAGE DETECTOR
HIGH-WITHSTAND VOLTAGE BUILT-IN DELAY CIRCUIT (EXTERNAL DELAY TIME SETTING) VOLTAGE DETECTOR
S-1011 Series
Rev.1.2_00
2. 2 S-1011 Series E / G type
Table 18
Item
Detection voltage*1
Hysteresis width
Symbol
Condition
−VDET VDD = 16.0 V, 5.0 V ≤ −VDET(S) ≤ 10.0 V
VHYS
VDD = 16.0 V
E type
G type*2
(Ta = +25°C unless otherwise specified)
Min.
Typ.
Max.
Unit
Test
Circuit
−VDET(S)
× 0.985
−VDET(S)
−VDET(S)
× 1.015
V
1
−VDET −VDET −VDET
× 0.030 × 0.050 × 0.080
V
1
−
0
−
V
1
Current
consumption*3
ISS
VDD = 16.0 V, VSENSE = −VDET − 0.1 V,
5.0 V ≤ −VDET ≤ 10.0 V
Operation voltage
VDD
−
Output transistor
−
0.55 1.55 μA
2
3.0
−
36.0 V
1
Output current
IOUT
Nch
VDD = 5.0 V, VSENSE = 4.5 V
0.5
−
VDS*4 = 0.05 V
−
mA 3
Leakage current
ILEAK
Output transistor VDD = 30.0 V, VOUT = 30.0 V,
Nch
VSENSE = 30.0 V
−
−
2.0
μA
3
Detection delay time*5 tRESET CN = 3.3 nF
8.0
10.0 12.0 ms
4
Release delay time*6 tDELAY CP = 3.3 nF
8.0
10.0 12.0 ms
4
SENSE pin resistance RSENSE
−
26.0
−
400 MΩ 2
CP pin discharge
ON resistance
RCP
VDD = 4.5 V, VSENSE = 14.0 V, VCP = 0.5 V
0.30
−
2.60 kΩ
−
CN pin discharge
ON resistance
RCN
VDD = 4.5 V, VSENSE = 4.5 V, VCN = 0.5 V
0.63
−
2.60 kΩ
−
*1. −VDET: Actual detection voltage value, −VDET(S): Set detection voltage value
*2. Hysteresis width is "unavailable", so release voltage = detection voltage.
*3. The current flowing through the SENSE pin resistance is not included.
*4. VDS: Drain-to-source voltage of the output transistor
*5. The time period from when the pulse voltage of −VDET(S) + 1.0 V → −VDET(S) − 1.0 V is applied to the SENSE pin to
when VOUT reaches VDD / 2, after voltage of 16.0 V is applied to the VDD pin and the SENSE pin input voltage (VSENSE)
reaches the release voltage once.
*6. The time period from when voltage of 16.0 V is applied to the VDD pin and the pulse voltage of −VDET(S) − 1.0 V →
−VDET(S) + 1.0 V is applied to the SENSE pin to when VOUT reaches VDD / 2.
12