English
Language : 

SDA9206 Datasheet, PDF (45/54 Pages) Siemens Semiconductor Group – ADC with Built in Antialiasing filter and Clock generation UnitS
SDA 9206
3.1 Recommended Operating Conditions
Parameter
Symbol
Limit Values
Unit
min. nom. max.
Ambient temperature TA
0
Power Requirements
25 70
°C
Analog supply voltage VADDx 4.75
5.0 5.25
V
Digital supply voltage VDD
4.75 5.0 5.25 V
DTO supply voltage VDDDTO 4.75
5.0 5.25
V
Output stage supply VDDQ
4.75
5.0 5.25
V
voltage
3.0
3.3 3.6
V
Supply voltage
differential
VDD, diff - 0.25
0.25 V
All TTL Inputs
H-input voltage
VIH
2.0V
VDDQ
1
L-input voltage
VIL
0
0.8
V
I2C-Bus (Values are Referred to min. (VIH) and max. (VIL))
H-input voltage
VIH
0.7 x VDDQ
VDD
1
L-input voltage
VIL
0V
0.3 x VDDQ 1
SCL clock frequency fSCL
0
400
kHz
Rise times
tR
of SCL, SDA
0.3
µs
Fall times
tF
of SCL, SDA
0.3
µs
Set-up time data
tSU, Dat 100
ns
Hold time data
tHD, Dat 0
ns
Bus free time before tBuf
1.3
µs
start condition
Set-up time start
tSU, Sta 0.6
µs
condition
Hold time start
tHD, Sta 0.6
µs
condition
Remark
5 V-Mode
3.3 V mode, only
to be used for
FORMAT = 00
Supply pins VADDx
Semiconductor Group
45
1999-02-10