Table 5-1: GV7704 Register Descriptions — Channel Controls (Continued)
Address
Register Name
Parameter Name
Bit
Slice
4863h (Ch 0)
5463h (Ch 1) EXTRACT_STREAM_ID_ EXTRACT_STREAM_ID_
6063h (Ch 2)
REG1
BYTE1
7:0
6C63h (Ch 3)
4864h (Ch 0)
5464h (Ch 1) EXTRACT_STREAM_ID_ EXTRACT_STREAM_ID_
6064h (Ch 2)
REG2
BYTE2
7:0
6C64h (Ch 3)
4865h (Ch 0)
5465h (Ch 1) EXTRACT_STREAM_ID_ EXTRACT_STREAM_ID_
6065h (Ch 2)
REG3
BYTE3
7:0
6C65h (Ch 3)
4866h (Ch 0)
5466h (Ch 1) EXTRACT_STREAM_ID_ EXTRACT_STREAM_ID_
6066h (Ch 2)
REG4
BYTE4
7:0
6C66h (Ch 3)
4867h (Ch 0)
5467h (Ch 1) EXTRACT_STREAM_ID_ EXTRACT_STREAM_ID_
6067h (Ch 2)
REG5
BYTE5
7:0
6C67h (Ch 3)
4868h (Ch 0)
5468h (Ch 1) EXTRACT_STREAM_ID_ EXTRACT_STREAM_ID_
6068h (Ch 2)
REG6
BYTE6
7:0
6C68h (Ch 3)
487Dh (Ch 0)
547Dh (Ch 1)
INS_ID_BYTE1_REG
INS_ID_BYTE1
7:0
607Dh (Ch 2)
6C7Dh (Ch 3)
487Eh (Ch 0)
547Eh (Ch 1)
INS_ID_BYTE2_REG
INS_ID_BYTE2
7:0
607Eh (Ch 2)
6C7Eh (Ch 3)
R/W
Reset
Value
Description
Extract byte 1 information for the
RO
0h packet on DS1 (First UDW in the
Stream ID packet)
Extract byte 2 information for the
RO
0h packet on DS1 (First UDW in the
Stream ID packet)
Extract byte 3 information for the
RO
0h packet on DS1 (First UDW in the
Stream ID packet)
Extract byte 4 information for the
RO
0h packet on DS1 (First UDW in the
Stream ID packet)
Extract byte 5 information for the
RO
0h packet on DS1 (First UDW in the
Stream ID packet)
Extract byte 6 information for the
RO
0h packet on DS1 (First UDW in the
Stream ID packet)
RWC
0h Identification code byte 1
RWC
0h Identification code byte 2
GV7704
Preliminary Data Sheet Rev.3
PDS-060376
September 2015
www.semtech.com
39 of 52
Semtech